IEC标准对应表.docx
- 文档编号:9898024
- 上传时间:2023-02-07
- 格式:DOCX
- 页数:8
- 大小:17.42KB
IEC标准对应表.docx
《IEC标准对应表.docx》由会员分享,可在线阅读,更多相关《IEC标准对应表.docx(8页珍藏版)》请在冰豆网上搜索。
IEC标准对应表
62271-203@IEC:
2003
CommonnumberingofIEC62271publicationsfallingundertheresponsibilityofsubcommitteesSC17AandSC.17c
IEC62271series
HIGH-VOLTAGESWITCHGEARANDCONTROLGER
高压开关设备和控制设备
OldIECnumberifany
part
Newtitle
1
Commonspecifications
通用说明
IEC60694
2
Seismicqualificationforratedvoltagesof72.5Kvandabove
72.5kV及以上设备抗地震性能
-
100
High-voltagealternatingcurrentcircuit-breakers
高压交流断路器
IEC60056
101
Synthetictesting
合成测试
IEC60427
102
High-voltagealternatingcurrentdisconnectionsandearthingswitches高压交流隔离开关和接地开关
IEC60129
103
Switchesforratedvoltagesabove1kVandlessthan52kV
1kV~52kV的开关设备
IEC60265-1
104
Switchesforratedvoltagesof52kVandabove
52kV及以上的高压开关设备
IEC60265-2
105
Alternatingcurrentswitch-fusecombinations
高压交流开关-熔断器组合
IEC60420
106
Alternatingcurrentcontactorsandcontactor-basedmotor-starters
交流接触器和
IEC60470
107
Alternatingcurrentswitchgear-fusecombinations
高压交流开关设备-熔断器组合
-
108
Switchgearhavingcombinedfunction
开关设备的联动功能
-
109
Seriescapacitorby-passswitches
串连电容器
-
200
ACmetal-enclosedswitchgearandcontrolgearforratedvoltageabove1kVanduptoandincluding52kV
1kV~52kV交流金属封闭开关和控制设备
IEC60298
201
Insulation-enclosedswitchgearandcontrolgearforratedvoltageuptoandincluding52kV
52kV及以上绝缘封闭开关设备
IEC60466
202
High-voltage/Low-voltageprefabricatedsubstations
高低压箱式变电站
IEC61330
203
Gas-insulatedmetal-enclosedswitchgearforratedvoltagesabove52kV
额定电压在52kV以上气体绝缘金属封闭开关设备
IEC60517
204
High-voltagegas-insulatedtransmissionlinesforratedvoltagesof72.5kVandabove
额定电压在72.5kV及以上高压气体绝缘输电线路
IEC61640
(300)
Guideforseismicqualificationofhigh-voltagealternatingcurrentcircuit-breakers
高压交流断路器地震条件导则
IEC61166
(301)
Guideforinductiveloadswitching感应负载开关导则(高压交流断路器)
IEC61223
(302)
Guideforshort-circuitandswitchingtestproceduresformetal-enclosedanddeadtankcircuit-breakers
金属封闭和落地罐式断路器的短路和开合试验程序导则
IEC61633
(303)
Useandhandlingofsulphurhexafluoride(SF6)inhigh-voltageswitchgearandcontrolgear
高压开关和控制设备种SF6的使用和操作
IEC61634
(304)
Additionalrequirementsforenclosedswitchgearandcontrolgearfrom1kVto72.5kVtobeusedinseversclimaticconditions
1kV到72.5kV封闭开关和控制设备用在特殊环境条件下的附加要求
IEC60932
(305)
Cableconnectionsforgas-insulatedmetal-enclosedswitchgearforratedvoltagesabove52kV.
52kV及以上气体绝缘金属封闭开关设备的电缆连接
IEC60859
(306)
Directconnectionbetweenpowertransformersandgas-insulatedmetal-enclosedswitchgearforratedvoltagesabove52kV.
52kV及以上发电机变压器和气体绝缘金属封闭开关设备的直接连接
IEC61639
(307
Useofelectronicandassociatedtechnologiesinauxiliaryequipmentofswitchgearandcontrolgear
开关设备和控制设备的辅助设备种电气和相关技术的使用
IEC62063
(308)
Guideforasymmetricalshort-circuitbreakingtestdutyT100a
非对称短路开端试验导则
-
(309)
TRVparametersforhigh-voltageswitchgearandcontrolgearforratedvoltagesabovelkVandlessthan100kV.
-
(310)
Electricalendurancetestingforcircuit-breakersrated72.5kVandabove
72.5kV及以上的断路器的电动力续性试验
-
62271-2003◎IEC:
2003
Table102-Preferredratedinsulationlevelsforratedvoltages
forequipmentofrange1
Ratedvoltageforequipment
Ur
kV
设备额定电压
Ratedshort-durationpower-frequencywithstandvoltage
(额定短时工频耐受电压)
Ud
kV
Ratedlightningimpulsewithstandvoltage
(额定雷电冲击耐受电压)
Up
kV(peckvalue)
Phase-to-earth,acrossopenswitchingdeviceandbetweenphase
相对地,相间和通过断开的设备
Acrosstheisolatingdistance
通过的绝缘距离
Phase-to-earth,acrossopenswitchingdeviceandbetweenphase
相对地,相间和通过断开的设备
Acrosstheisolatingdistance
通过的绝缘距离
(1)
(2)
(3)
(4)
(5)
72.5
140
160
325
375
100
185
210
450
520
123
230
265
550
630
145
275
315
650
750
170
325
375
750
860
245
460
530
1050
1200
NOTEValuesincolumn
(2)areapplicable
A)Fortypetests,phase-to-earthandbetweenphases;
B)Forroutinetests,phase-to-phase,andacrosstheopenswitchingdevice.
Valuesincolumns(3),(4)and(5)areapplicablefortypetestsonly.
注意:
第二列的电压用于:
(1)相对地和相间的测试类型
(2)第三、四、五列种的电压值仅适用于相对地,相间和通过断开的开关设备的常规测试,
62271-2003◎IEC:
2003
Table103-Preferredratedinsulationlevelsforratedvoltages
forequipmentofrangeII
Ratedvoltageforequipment
Ur
kV
设备额定电压
Ratedshort-durationpower-frequencywithstandvoltage
(额定短时工频耐受电压)
Ud
kV
Ratedswitchingimpulsewithstandvoltage
(额定开关冲击耐受电压)
Us
kV
Ratedlightningimpulsewithstandvoltage
(额定雷电冲击耐受电压)
Up
kV(peckvalue)
Phase-to-earth,andbetweenphase(note3)
相对地和相间
acrossopenswitchingdeviceand/orisolatingdistance
(note3)
Phase-to-earth,andacrossopenswitchingdevice
相对地和相间
betweenphase
(note4)
相间
Acrossisolatingdistance(note1,2and3)
通过绝缘距离
Phase-to-earth,andbetweenphase
相对地和相间
acrossopenswitchingdeviceand/orisolatingdistance
(note3)
通过断开的开关设备和/或绝缘距离
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
300
460
595
850
1275
700(+245)
1050
1050(+170)
362
520
675
950
1425
800(+295)
1175
1175(+205)
420
650
815
1050
1575
900(+345)
1425
1425(+240)
550
710
925
1175
1760
900(+450)
1550
1550(+315)
800
960
1270
1425
2420
1100(+650)
2100
2100(+453)
NOTE1column(6)isalsoapplicabletosomecircuit-breakers,seeIEC62271-100.
NOTE2incolumn(6),valuesinbracketsarethepeckvaluesofthepower-frequencyvoltageUr/√2/√3appliedtotheoppositeterminal(combinedvoltage)
Incolumn(8),valueinbracketsarethepeckvaluesofthepower-frequencyvoltage0.7Ur/√2/√3appliedtotheoppositeterminal(combinedvoltage).seeannexDofIEC60694.
NOTE(3)Valuesincolumn
(2)areapplicable:
(a)fortypetests,phase-to-earthandbetweenphases;
(b)forroutinetests,phase-to-earth,phase-to-phase,andacrosstheopenswitchingdevice.
Valuesincolumns(3),(4),(5),(6),(7)and(8)areapplicablefortypetestsonly.
NOTE(4)thesevaluesarederivedusingthemultiplyingfactorsstatedinTable3ofIEC60070-1(1993)
注1:
第6列也适用于一些断路器,参见IEC62271-100.
注2:
在第6列,括号内的数字是加在同一极相应端子上的反极性工频电压的峰值。
注3:
第二列种的数字适用于:
相间试验类型
相对地,相间和通过断开的开关设备间的常规测试
(3),(4),(5),(6),(7)和(8)列种的数值仅用于典型测试
注4:
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEC 标准 对应