极进网络设备配置基本手册.docx
- 文档编号:7446218
- 上传时间:2023-01-24
- 格式:DOCX
- 页数:21
- 大小:28.53KB
极进网络设备配置基本手册.docx
《极进网络设备配置基本手册.docx》由会员分享,可在线阅读,更多相关《极进网络设备配置基本手册.docx(21页珍藏版)》请在冰豆网上搜索。
极进网络设备配置基本手册
ExtremeNetworks
EXOSQuickGuide
Justenoughtobedangerous
Contents
ExtremeNetworks1
EXOSCheatSheet1
EXOSSwitchBasics1
Manuals1
ConnectingtotheSwitch1
BasicCLINavigation1
Portnumbering1
System-levelComponents3
Software3
Loadnewsoftware3
Selectthenextimagetobebooted4
Reboot4
Hardware4
Typeofsystem4
PowerSupplies4
Fans4
Serialnumbers4
Totalservicetime4
Licenselevels4
Date&timeinformation4
Filestorage4
ManagingConfigurations5
Lookatthecurrentconfiguration5
CLIPaging5
BootingConfigurationFiles5
Savingaconfigurationfile5
Backingupaconfigfileto/fromaTFTPserver6
Resettheswitchtofactorydefaults6
UsingPorts7
ConfiguringPortSpeedandDuplex7
EnablingandDisablingPorts7
ExaminingPortConfigurations7
VLAN/PortMembership7
PortUtilization7
MonitorQoSbehavior7
LinkAggregation8
LACP8
UsingVLAN's9
CreateaVLAN9
AssignanIPaddresstoaVLAN9
Assignan802.1QtagvaluetotheVLAN9
Addanddeleteportsto/fromaVLAN9
GiveaQoSprofiletoaVLAN10
ExaminingVLANs10
FDBOperations11
IPRouting12
ShowtheRouteTable12
ShowtheIPInterfacesontheswitch12
TheARPCache12
EnableRouting12
CreateStatic/DefaultRoute13
OSPF13
SettheOSPFrouterid13
CreateanOSPFarea13
SettheOSPFrouterpriority13
TurnonOSPFforaVLAN13
TurnoffOSPFforaVLAN13
SeethestatusofOSPF13
LookattheOSPFNeighbors13
LookattheOSPFLSDB14
VRRP14
ConfigureVRRP14
ExamineVRRP14
TurnonSNTP14
EnableWebAccess:
14
SNMP14
SNMPSystemName14
AdvancedConfigurationExamples15
EAPS15
TurnonaDHCPserveronatestVLAN15
Bootprelay15
Mirroring(SpanPort)16
EXOSSwitchBasics
Manuals
Thisisjustanunofficalcheatsheet.There’slotsmoreinformationintheofficialmanuals.
FromtheExtremeWebSite()
∙HardwareInstallationGuides
oHowtoinstallthehardware,ofcourse,butalsotechnicalspecsonthegear(electricalpowerrequirements,heatgenerated,etc.
∙CommandReference
oDocumentsthesyntaxofeverycommandandeveryoption
∙ConceptsGuide
oExplainsthetechnologiesandconceptsbehindthem.Probablythemostusefulmanual.
oAppendixAexplainswhatsoftwarefeaturesaresupportedateachlicenselevel
Fromthesoftwareupdatesite
∙Releasenotes
oDocumentsnewfeaturesandhardware
oExplainshowtoupgradesoftware
oHastheengineeringlimitsforthatreleaseofcode.Forexample,howmanyIPv6routescanbelearnedbytheswitchrunningthatversionofcodecanbefoundinthereleasenotes.
oBugsthathavebeenfixedandbugsthatExtremeknowsabout
oProbablythesecondmostusefulmanual.
ConnectingtotheSwitch
UseaDB9malenull-modem(laplink)cable
SetthePCserialportto9600-n-8-1witheitherXON/XOFFornoflowcontrol
Note:
Donotusehardwareflowcontrol.TheExtremeswitchdoesnotuseitandwillneverassertCTS.
BasicCLINavigation
-Defaultlogin:
'admin'withnopassword.
-Useup/downarrowkeystoscrollthroughthecommandhistory
-Useleft/rightarrowkeystoeditacommand
-Use
>toseewhatcommandsareavailablenext
-Use
-Commandscanbeabbreviatedsolongastheabbreviationisunique
-Commandsalwaysstartfromtherootlevel.EXOSdoesn’tchangecommandlevels.
-#signsatthestartofthelineindicateacommentfollows(usuallyonlyseeninconfigurationfiles)
Portnumbering
Instandaloneswitches(notstacked,notinachassis),portsareidentifiedbytheirnumber1,2,3,4,etc.
Whenswitchesarestackedorforportsinachassis,portsareidentifiedby
1,2:
24,etc.
Youcanuselistsofportsseparatedbycommas:
1,17,23or1:
1,2:
27,3:
23
Youcanuseportranges:
1-12or4:
4-4:
14.Inthelatercase,4:
4-14alsoworks.
Youcanalsomixthelistsandranges:
1-4,23or4:
4-14,5:
7
System-levelComponents
Software
EXOSswitchesstoretwoversionsofcodeinnon-volatileRAM.ThetwoversionsarecalledPrimaryandSecondary,butthatdoesnotmeanthatPrimaryistriedfirstandifitfailstoworkthenSecondaryistried.PrimaryandSecondaryarejustnames.The“showswitch”commandwillletyouseewhatversionsofsoftwareareloadedintotheswitch,versiontheswitchisrunningon(“ImageBooted”),andwhatversionwillbeloadedthenexttimetheswitchboots(“ImageSelected”).
VDB.1#showswitch
SysName:
VDB
SysLocation:
SysContact:
support@,+18882573000
SystemMAC:
00:
04:
96:
26:
6D:
76
SystemType:
X450e-48p
SysHealthcheck:
Enabled(Normal)
RecoveryMode:
All
SystemWatchdog:
Enabled
CurrentTime:
TueSep2022:
13:
162011
Timezone:
[AutoDSTDisabled]GMTOffset:
0minutes,nameisUTC.
BootTime:
TueSep2022:
11:
282011
BootCount:
283
NextReboot:
Nonescheduled
SystemUpTime:
1minute48seconds
CurrentState:
OPERATIONAL
ImageSelected:
primary
ImageBooted:
secondary
Primaryver:
12.5.2.6
Secondaryver:
12.4.2.17
ConfigSelected:
primary.cfg
ConfigBooted:
primary.cfg
primary.cfgCreatedbyExtremeXOSversion12.5.2.6
278372bytessavedonTueAug3014:
27:
292011
Loadnewsoftware
EXOSwon’tletyoureplaceyourbootedversion.Soifyoubootedonthesecondaryimage,youcanonlyloadnewcodeintotheprimaryimageslot.EXOSnowhandlestheslotselectionforyouautomatically.Setupatftpserverwiththenewsoftwareandthenloaditontotheswitchwiththecommand
downloadimage
Unlessyouareactuallyusingthemanagementportintheback,youhavetoincludethe“vrvr-default”businessattheendofthecommand.
Here’sanactualexample
downloadimage192.168.1.27summitX-12.6.1.3.xosvrvr-default
Onveryrareoccasions,youmightalsoneedtoloadnewbootcodeontotheswitchbeforeyourunnewsoftware.Thereleasenoteswilltellyouifyourcurrentbootcodeiscompatible.Ifyoudoneedtodownloadanewbootrom,thendon’tdoitjustbecauseyoucan.However,ifyoudoneedanewbootrom,thecommandisalmostidentical:
downloadbootrom192.168.1.27pmon_summitl-1.0.5.6.xtrvrvr-default
Selectthenextimagetobebooted
useimageprimary
useimagesecondary
Reboot
Reboot
Hardware
Typeofsystem
showswitch
PowerSupplies
showpower
Fans
showfans
Serialnumbers
showversion
Switch:
800190-00-020634G-00406Rev2.0BootROM:
1.0.5.5IMG:
12.5.2.6
XGM2-1:
N/AN/ARev0.0
Image:
ExtremeXOSversion12.5.2.6v1252b6byrelease-manager
onTueMar117:
38:
45PST2011
BootROM:
1.0.5.5
Totalservicetime
showodometers
ServiceFirstRecorded
FieldReplaceableUnitsDaysStartDate
---------------------------------------------------------------
Switch:
X450e-48p493Sep-20-2006
Licenselevels
showlicense
Date&timeinformation
showswitch
tellsthecurrentdateandtime,thetimezeone,andwhentheswitchwasbooted.
Filestorage
BecauseEXOSrunsonaLINUXkernel,thefilesystemcommandsareveryLINUX-like.
∙Directorylisting–ls
∙Copyafile–cp
∙Renameafile–mv
∙Deleteafile–rm
ManagingConfigurations
Lookatthecurrentconfiguration
showconfig
showsthecurrentlyrunningconfiguration.
Defaultconfigurationsettingsaresuppressed.Ifyouwanttoseethemuse
showconfigdetail
Ifyouwanttoseetheconfigurationforaparticularmodule(e.g.vlan,IP,eaps,OSPF,etc.)youcanspecifyjustthatmodule
showconfigospf
CLIPaging
Bydefault,theCLIshowsyoua“page”of25linesatatimeandthenwaitsforyoutohitakeytocontinue.Thatcangetannoying,particularlyifyouhavesetyourterminalprogramtocapturetheoutputtoalogfile.Youcanturnoffthepage-by-pagedisplaywiththecommand
disableclipaging
Whenyou’redonescrollingouttheconfigfile,turnthepagingfeaturebackonwiththecommand
enableclipaging
BootingConfigurationFiles
EXOSallowsyoutostoreandusemultipleconfigurationfiles.
showswitch-Seewhichconfigurationfilewasbooted(“Configbooted”)andwhichfilewillbeusedatthenextboot(“Configselected”).
Savingaconfigurationfile
saveconfig-willwritethecurrentconfigtowhicheverfileisspecifiedin“Configselected”.
saveconfig
Note:
Eventhoughconfigfilesalwaysendin“.cfg”EXOSwillcomplainifyouaddtheextension.Sojustgiveitthenameofthenewconfig.
Example
saveconfigtest
Doyouwanttosaveconfigurationtotest.cfg?
(y/N)Yes
Savingconfigurationonmaster.............done!
Configurationsavedtotest.cfgsuccessfully.
Thecurrentselecteddefaultconfigurationdatabasetobootupthesystem
(primary.cfg)isdifferentthantheonejustsaved(test.cfg).
Doyouwanttomaketest.cfgthedefaultdatabase?
(y/N)No
Defaultconfigurationdatabaseselectioncancelled.
Backingupaconfigfileto/fromaTFTPserver
tftpput
tftpget
Example:
tftpput192.168.1.1vrvr-defaulttest.cfg
Note:
Youdon’tspecifythe“.cfg”extensionwhensavingfiles,butyoudowanttospecifythe“.cfg”whenusingtftp.
Note:
EXOSconfigfilesarestoredasXML,whichcanbehardforushumanstoread.EXOSandRidgelineidentifynormalASCIIfileswithanextensionof“xsf”.SotouploadtheconfiginASCIIformat,usethecommand
uploadconfiguration
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 网络设备 配置 基本 手册