美国ANSIAHAMAC1.docx
- 文档编号:7270830
- 上传时间:2023-01-22
- 格式:DOCX
- 页数:30
- 大小:137.26KB
美国ANSIAHAMAC1.docx
《美国ANSIAHAMAC1.docx》由会员分享,可在线阅读,更多相关《美国ANSIAHAMAC1.docx(30页珍藏版)》请在冰豆网上搜索。
美国ANSIAHAMAC1
AssociationofHomeApplianceManufacturers
MethodforMeasuringPerformanceof
PortableHouseholdElectricCord-Connected
RoomAirCleaners
ANSI/AHAMAC-1-2002
PREFACE
TheAssociationofHomeApplianceManufacturers(AHAM)developsstandardsinaccordancewithAHAM's"PolicyandProceduresGoverningTechnicalStandards"whichstates:
"AHAMStandardsshallbeinthebestinterest,mutually,ofconsumerswhouseappliances,theindustrieswhichprovideandserviceappliances,andotherinterestedparties.Theyshallrelatetoactualuseconditions,betechnicallyandscientificallysound."
UseorobservanceofAHAMstandardsisvoluntary.
AHAMstandardsarepresentedtotheAmericanNationalStandardsInstitute(ANSI)forrecognitionasAmericanNationalStandards.ThisstandardwassorecognizedonApril9,2002andbearstheAmericanNationalStandarddesignationANSI/AHAMAC-1-2002.
Thisstandardcontainstestprocedureswhichmaybeappliedtoanybrandormodelofportablehouseholdelectriccord-connectedroomaircleanerswithinthestatedconfinesofthestandard'slimitsofmeasurabilityformeasuringperformance.Resultsoftestsinaccordancewiththisstandardmaybepubliclystated.
Withregardtosafety,AHAMrecommendsthatallapplianceproducts-bothmajorandportable-manufacturedormarketedintheUnitedStatesbesubmittedtoanappropriateindependentlaboratoryforinspectionandlistinginconformancewiththesafetystandardsandproceduresfollowedbysuchlaboratories.TherelevantstandardsforportablehouseholdelectriccordconnectedroomaircleanersareUL867,"StandardforElectrostaticAirCleaners"andUL507,"StandardforFans."
Theappendicestothisstandardaregenerallyforinformationalpurposesexceptwherereferencedinthebodyofthestandard.
AHAMwelcomescommentsandsuggestionsregardingthisstandard.Anystandardmaybereviewedandimprovedasneeded.Allstandardsmustbeupdatedorreconfirmedatleasteveryfiveyears.Anyinterestedparty,atanytime,mayrequestachangeinanAHAMstandard.SuchrequestshouldbeaddressedtoAHAM'sPresident,andshouldbeaccompaniedbyastatementofreasonfortherequestandasuggestedalternateproposal.
Thisstandardmayinvolvehazardousmaterials,operations,andequipment.Thisstandarddoesnotpurporttoaddressallofthesafetyproblemsassociatedwithitsuse.Itistheresponsibilityofwhomeverusesthisstandardtoconsultandestablishappropriatesafetyandhealthpracticesanddeterminetheapplicabilityofanyregulatorylimitationspriortouse
Copyright©2002bytheAssociationofHomeApplianceManufacturers
TABLEOFCONTENTS
1.PURPOSE1
2.SCOPE1
3.DEFINITIONS1
3.1PortableHouseholdElectricCord-ConnectedRoomAirCleaner1
3.2TypesofPortableHouseholdElectricCord-ConnectedRoomAirCleaners2
3.3TestParticulateMatter2
3.4TestChamber2
3.5AirCirculatingEquipment2
3.6ParticulateMatterRemoval3
3.7HighEfficiencyParticulateAir(HEPA)Filter3
3.8AerosolGenerator3
3.9AerodynamicParticleSize3
3.10TerminalVelocity3
3.11ParticleNumberConcentration3
3.12AerosolSpectrometer3
3.13CigaretteSmokeDiluter3
3.14NaturalDecay3
3.15CleanAirDeliveryRate(CADR)4
4.GENERALCONDITIONSFORMEASUREMENT4
4.1ElectricalSupply4
4.2TestChamberAmbientTemperature4
4.3ChamberAirExchangeRate4
4.4ChamberParticulateorIonConcentrations4
4.5ChamberEquipment5
4.6TestEquipmentPreparation5
5.TESTPROCEDUREFORDETERMININGPERFORMANCEONCIGARETTESMOKE.5
5.1NaturalDecayMeasurement5
5.2ParticulateMatterRemovalMeasurement7
6.TESTPROCEDUREFORDETERMININGPERFORMANCEONTESTDUST8
6.1NaturalDecayMeasurement8
6.2ParticulateMatterRemovalMeasurement10
7.TESTPROCEDUREFORDETERMININGPERFORMANCEONPAPERMULBERRYPOLLEN11
7.1NaturalDecayMeasurement11
7.2ParticulateMatterRemovalMeasurement13
8.CALCULATIONPROCEDURES14
8.1CriteriaforEliminationofDataPointsfromanAC-1Run14
8.2CalculatingtheDecayConstant15
8.3ComputationoftheStandardDeviationEstimatefortheSlopeofOneRegressionLine15
8.4PerformanceCalculation16
8.5CalculationoftheStandardDeviationEstimateoftheCADRforaSingleTest16
9.SAFETY17
APPENDIXA18
APPENDIXB23
APPENDIXC24
APPENDIXD28
1.PURPOSE
Thisstandardmethodestablishesuniform,repeatableproceduresandstandardmethodsformeasuringspecifiedproductcharacteristicsofportablehouseholdelectriccord-connectedroomaircleaners.
Thestandardmethodsprovideameanstocompareandevaluatedifferentbrandsofportablehouseholdelectriccordconnectedroomaircleanersregardingcharacteristicssignificanttoproductuse.
Thestandardmethodsofmeasurementarenotintendedtoinhibitimprovementandinnovationinproducttesting,designorperformance.
2.SCOPE
Thisstandardmethodappliestoportablehouseholdelectriccord-connectedroomaircleanersasdefinedinSection3.
Thisstandardmethodincludesdefinitionsandsafetycharacteristicsofportablehouseholdelectriccord-connectedroomaircleanersofthetypesindicated.
Thisstandardmethodmeasurestherelativereductionbytheaircleanerofparticulatemattersuspendedintheairinaspecifiedtestchamber.
Thisstandardmethodhasdefinedlimitsofmeasurability.Thestatisticalvalidityoftestresultsoutsideofthestatedpracticallimitsisquestionableandunevaluated.Thepracticallimitsofmeasurabilityare:
Dust10to400CADR
Tobaccosmoke10to400CADR
Pollen25to450CADR
TheprecisionoftheStandardasbasedona0CADRaircleanerexpressedas2standarddeviationlimits(95%)are:
Dust+10CADR
Tobaccosmoke+10CADR
Pollen+25CADR
3.DEFINITIONS
3.1PortableHouseholdElectricCord-ConnectedRoomAirCleaner
Anelectriccord-connectedappliancewiththefunctionofremovingparticulatematterfromtheairandwhichcanbemovedfromroomtoroom.
3.2TypesofPortableHouseholdElectricCord-ConnectedRoomAirCleaners
3.2.1FanwithFilter
Aircleanerswhichoperatewithanelectricalsourceofpowerandcontainamotorandfanfordrawingairthroughafilter(s).
3.2.2FanwithFilterandElectrostaticPlates
Aircleanerswhichoperatewithafanandfilter(s)thatincorporateelectricallychargedplatesorwirestoelectrostaticallycollectparticulatematter.
3.2.3FanFilterwithIonGenerator
AirCleanersthatincorporateaniongeneratorinadditiontoafanandfilter.
3.2.4IonGenerator
Aircleanerswhichincorporateaniongeneratoronly.
3.2.5OtherTypes
Adevicewhichhasthestatedcapabilitytoreducetheconcentrationofparticulatematterinaroom.
3.3TestParticulateMatter
3.3.1CigaretteSmoke
Smokeproducedbyburningcigarettetobaccowithairforcedthroughthecigarette'sfilterhavingparticlesizesrangingfrom0.09mto1.0mdiameter.
3.3.2AirCleanerFineFractionTestDust(ArizonaRoadDust)
Commerciallyavailabletestdustwithparticlesizesrangingfrom0.5mto3.0m.
3.3.3Pollen
Particulatematternaturallyoccurringfromplants.ThepollentobeusedisPaperMulberryPollen(non-defatted)withaparticlesizerangeof5mto11m,includingfragments.
3.4TestChamber
Theroomsizechamberfordeterminingperformanceinremovingparticulatematterfromtheair.(ThespecificationsforAHAM'schamberareinAppendixA.)
3.5AirCirculatingEquipment
3.5.1MixingFan
Ahighvolumeceilingfanusedtomixthechamberduringcontaminantaerosolgeneration.
3.5.2RecirculationFan
Afancapableofproducing300-400cfmforthepurposeofmaintainingahomogeneousenvironmentwithinthechamber.
3.6ParticulateMatterRemoval
Thereductionofparticlenumberconcentrationinairduetotheoperationoftheaircleaner.
3.7HighEfficiencyParticulateAir(HEPA)Filter
Anairfilterwithgreaterthanorequalto99.97%removalofdioctylphthalateat0.3mdiameter.
3.8AerosolGenerator
Adevicewhichproducesanddisseminatessmallparticlesintoair.
3.8.1SmokeGenerator
AnaerosolgeneratorwhichdisseminatestesttobaccosmokewithparticlesizesspecifiedinSection3.3.1intotheair.
3.8.2DustGenerator
AnaerosolgeneratorwhichdisseminatestestdustwithparticlesizesspecifiedinSection3.3.2intotheair.
3.8.3PollenGenerator
AnaerosolgeneratorwhichdisseminatestestpollenwithparticlesizesspecifiedinSection3.3.3intotheair.
3.9AerodynamicParticleSize
Aclassificationofparticlesizesasspheresofunitdensitybasedonterminalvelocities.
3.10TerminalVelocity
Themaximumvelocityachievedbyaparticleundergivenconditions.
3.11ParticleNumberConcentration
Numberofparticlespercubiccentimeterofroomair.
3.12AerosolSpectrometer
Deviceformeasuringparticlesizedistributioninroomair.
3.13CigaretteSmokeDiluter
Deviceforreducingtheconcentrationofsmokebyaknownfactortoalevelsuitableformeasurement.
3.14NaturalDecay
Thereductionofparticulatematterduetothenaturalphenomenainthetestchamber,principallysedimentation,agglomerationandsurfacedeposition.
3.15CleanAirDeliveryRate(CADR)
Themeasureofaircleanerperformancebythistestprocedure.SeeSection8.5.
WithinthescopeofANSI/AHAMAC-1,CleanAirDeliveryRate(CADR)isdefinedasthemeasureofthedeliveryofcontaminantfreeairbyaportablehouseholdelectriccord-connectedroomaircleaner,expressedincubicfeetperminute.Moretechnically,CleanAirDeliveryRatesaretheratesofcontaminantreductioninthetestchamberwhentheunitisturnedon,minustherateofnaturaldecaywhentheunitisnotrunning,timesthevolumeofthetestchamberasmeasuredincubicfeet.(SeeSection