文献翻译静力弹塑性分析法在侧向荷载分布方式下的评估研究
EVALUATIONOFLATERALLOADPATTERN
INPUSHOVERANALYSIS
ArmaganKORKMAZ1,AliSARI2
1VisitorResearcher,DepartmentofCivilEngineering,UniversityofTexasatAustin,Austin,TX78712,PH:
512-232-9216;armagan@mail.utexas.edu
2Ph.D.Student,DepartmentofCivilEngineering,UniversityofTexasatAustin,Austin,TX78712,PH:
512-232-9216;ali_sari@mail.utexas.edu
ABSTRACT
Theobjectiveofthisstudyistoevaluatetheperformanceoftheframestructuresorvariousloadpatternsandvarietyofnaturalperiodsbyperformingpushoverandnonlineardynamictimehistoryanalyses.Theloaddistributionsforpushoveranalysesarechosenastriangular,IBC(k=2)andrectangular.Fourdifferentframedstructuresareused,whicharetypicalreinforcedconcrete(R\C)framesystemsandhavefourdifferentnaturalperiods.EventhoughthenonlineardynamictimehistoryanalysisisthebestwaytocomputeseismicdemandsFEMA-273andATC-40proposestouseofnonlinearstaticprocedureorpushoveranalysis.Thispaperisalsointendedtocomparetheresultsofpushoverandnonlineardynamictimehistoryanalyses.Toevaluatetheresultsfromthepushoveranalysesforthreeloadpatternsandalsofournaturalperiods,nonlineardynamictimehistoryanalysesareperformed.Earthquakegroundmotionsrecordedat50stationsduringvariousearthquakesoveralltheworldareusedintheanalyses.Pushoverandnonlineartimehistoryanalysesresultsarecomparedtochoosethebestloaddistributionforspecificnaturalperiodforthistypeofframestructure.
Keywords:
Pushoveranalysis,nonlineartimehistory,loadpatterns,moment-resistingframe
INTRODUCTION
Onlythelifesafetyandcollapsepreventioningeneralearthquakeresistantdesignphenomenaareexplicitlypreventedinseismicdesigncodes.Thedesignisgenerallybasedonevaluatingtheseismicperformanceofstructures.Itisrequiredtoconsiderinelasticbehaviorwhileevaluatingtheseismicdemandsatlowperformancelevels.FEMA-273andATC-40usepushoveranalysisasnonlinearstaticanalysisbutnonlineartimehistoryanalysishasmoreaccurateresultsoncomputingseismicdemands(ATC-40,1996,FEMA-273,1997).Thepurposesinearthquake-resistancedesignare:
(a)topreventnon-structuraldamageinminorearthquakes,whichmayoccurfrequentlyinlifetime,(b)topreventstructuraldamageandminimizenon-structuraldamageinmoderateearthquakeswhichmayoccuroccasionally,(c)topreventcollapsingorseriousdamageinmajorearthquakeswhichmayoccurrarely.Designsareexplicitlydoneonlyunderthethirdcondition.
Theobjectiveofthisstudyistoevaluatetheperformanceoftheframestructuresforvariousloadpatternsandvarietyofnaturalperiodsbyperformingpushoverandnonlineardynamictimehistoryanalyses.3,5,8and15storyR\Cframestructuresareusedintheanalysesandtheloaddistributionsforpushoveranalysesarechosenastriangular(IBC,k=1),IBC(k=2)andrectangular,wherekistheanexponentrelatedtothestructureperiodtodefineverticaldistributionfactor(IBC,2000).ThefourframestructureshavebeenanalyzedusingnonlinearprogramDRAIN-2D(Prakash,V.,Powell,G.,Campbell,S.,1993)andtheresultshavebeencomparedbyrecordedresponsedata.Bothnonlinearstaticpushoveranalysisandnonlineardynamictimehistoryanalysisareperformed.Thecorrelationsbetweenthesenonlinearanalysesarestudied.
Theperformanceofthebuildingssubjectedtovariousrepresentativeearthquakegroundmotionsisexamined.Finally,pushoverandnonlineartimehistoryanalysesresultsarecomparedtochoosethebestloaddistribution(pattern)forspecificnaturalperiodforthesetypesofreinforcedconcreteframestructures.
GROUNDMOTIONDATA
Forthisstudy,itisconsideredas50differentdatausedinthenonlineardynamictimehistoryanalyses,givenintheTable1.AllthedataarefromdifferentsiteclassesasA,B,CandD.TheshearvelocitiesforthesiteclassesA,B,CandDareVs>750m/s,360m/sto750m/s,180m/sto360m/s,and180m/s,respectively.Thegroundmotiondataarechosenfromdifferentdestructiveearthquakesaroundtheworldearthquakename,dateofearthquake,datasource,recordname,peakgroundaccelerations(pga)forthecomponents,effectivedurationsandfaulttypesforeachdataarepresentedintheTable1.,respectively.
Thepeakgroundaccelerationsareintherange0.046to0.395g,wheregisaccelerationduetogravity.Allgroundmotiondataarerecordedinnear-fieldregionasinmaximum20kmdistance.
DESCRIPTIONOFTHEFRAMESTRUCTURES
3,5,8and15-storyR\Cframestructureswithtypicalcross-sectionsandsteelreinforcementsareshowninFigure1.ThereinforcedconcreteframestructureshavebeendesignedaccordingtotherulesoftheTurkishCode.Thestructureshavebeenconsideredasanimportantclass1withsubsoiltypeofZ1andinseismicregion1.Thedead,liveandseismicloadshavebeentakenaccountduringdesign.
Allreinforcedconcreteframestructuresconsistthree-bayframe,spacedat800cm.Thestoryheightis300cm.Thecolumnsareassumedasfixedontheground.Yieldstrengthofthesteelreinforcementsis22kN/cm2andcompressivestrengthofconcreteis1.6kN/cm2.
Thefirstnaturalperiodofthe3-storyframestructureiscomputed0.54s.Thecross-sectionofallbeamsinthisframeisrectangular-shapeswith25cmwidthand50cmheight.Thecross-sectionofallcolumnsis30cmx30cm.Thefirstnaturalperiodof5-storyframestructureis0.72sandthecross-sectionofbeamsis25cmwidthand50cmheightsimilarto3-storyframe.Cross-sectionofcolumnsatthefirstthreestoriesis40cmx40cmandatthelasttwostories,itis30cmx30cm.Theeight-storyand15-storyframestructureshavenaturalperiodof0.90sand1.20s.Thecrosssectionofbeamsforbothframestructuresis25cmx55cm.The8-storyframestructurehas50cmx50cmcolumnsforthefirstfivestoriesand40cmx40cmforthelastthreestories.Thecrosssectionofcolumnsforfirsteightstoriesinthe15-storyframestructuresis80cmx80cmandatthelastsevenstories,itis60cmx60cm.
NONLINEARSTATICPUSHOVERANALYSISOFFRAMESTRUCTURES
Forlowperformancelevels,toestimatethedemands,itisrequiredtoconsiderinelasticbehaviorofthestructure.Pushoveranalysisisusedtoidentifytheseismichazards,selectionoftheperformancelevelsanddesignperformanceobjectives.InPushoveranalysis,applyinglateralloadsinpatternsthatrepresentapproximatelytherelativeinertialforcesgeneratedateachfloorlevelandpushingthestructureunderlateralloadstodisplacementsthatarelargerthanthemaximumdisplacementsexpectedindesignearthquakes(Li,Y.R.,1996).Thepushoveranalysisprovidesashearvs.displacementrelationshipandindicatestheinelasticlimitaswellaslateralloadcapacityofthestructure.Thechangesinslopeofthiscurvegiveanindicationofyieldingofvariousstructuralelements.Themainaimofthepushoveranalysisistodeterminememberforcesandglobalandlocaldeformationcapacityofastructure.Theinformationcanbeusedtoassesstheintegrityofthestructure.
Afterdesigninganddetailingthereinforcedconcreteframestructures,anonlinearpushoveranalysisiscarriedoutforevaluatingthestructuralseismicresponse.ForthispurposethecomputerprogramDrain2Dhasbeenused.Threesimplifiedloadingpatterns;triangular,(IBC,k=1),(IBC,k=2)andrectangular,wherekisanexponentrelatedtothestructureperiodtodefineverticaldistributionfactor,areusedinthenonlinearstaticpushoveranalysisof3,5,8and15-storyR\Cframestructures.
Loadcriteriaarebasedonthedistributionofinertialforcesofdesignparameters.Thesimplifiedloadingpatternsasuniformdistribution,triangulardistributionandIBCdistribution,theseloadingpatternsarethemostcommonloadingparameters.
VerticalDistributionofSeismicForces:
(1)
(2)
where:
Cvx=Verticaldistributionfactor
V=Totaldesignlateralforceorshearatthebaseofstructure
wiandwx=Theportionofthetotalgravityloadofthestructure
hiandhx=Theheightfromthebase
k=Anexponentrelatedtothestructureperiod
Inadditiontheselateralloadings,framesaresubjectedliveloadsanddeadweights.P-△effectshavebeentakenintotheaccountduringthepushoveranalyses.Thelateralforceisincreasedfor3,5and8-storyframesuntiltheroofdisplacementreached50cmand100cmfor15-storyframe.Beamandcolumnelementsareusedtoanalyzetheframes.Thebeamsareassumedtoberigidinthehorizontalplane.Inelasticeffectsareassignedtoplastichingesatmemberends.Strain-hardeningisneglectedinallelements.Bilinearmoment-rotationrelationshipisassumedforbothbeamandcolumnmembers.Axialload-Moment,P-M,interactionrelation,suggestedbyACI318-89,isusedasyieldingsurfaceofcolumnelements.Inertialmomentofcrackedsection,Icr,isusedforbothcolumnandbeammembersduringanalyses.Icriscomputedashalfofthegrossmomentofinertia,Ig.
TheresultsofthepushoveranalysesarepresentedinFigures2to5.Thepushovercurvesareshownforthreedistributions,andforeachframestructures.Thecurvesrepresentbaseshear-weightratioversusstoryleveldisplacementsforuniform,triangularandIBCloaddistribution.ShearVwascalculatedbysummingallappliedlateralloadsabovethegroundlevel,andtheweightofthebuildingWisthesummationoftheweightsofallfloors.Besidethese,thesecurvesrepresentthelostoflateralloadresistingcapacityandshearfailuresofacolumnatthedisplacementlevel.Thechangesinslopeofthesecurvesgiveanindicationofyieldingofvariousstruc