Clickonthelinksbelow.Section1BackgroundtofireresistanthydraulicfluidsSection2FireratingmethodsforfireresistanthydraulicfluidsandfluidselectionSection3HydraulicsystemsoverviewSection4TechnicalcomparisonbetweenCastrolAnvolSWXpropertiesandawell-knowncompetitorSection5ChangeoverproceduresandcompatibilitydataSection6TrialproceduresandoilconditionmonitoringSection7Casestudies
Background
Hydraulicsystemsareoneofthemostcommonsourcesofpowertransmissionfoundinsteelmills.Theyareusedintheoperationofmeltshops,rollingmills,reheatfurnaces,temperingfurnaces,heat-treatfurnacesandannealingfurnaces.Thefluidofchoiceformostengineersisonebasedonmineraloil.Itisinexpensiveandprovidesgoodsystemreliability.However,hydraulicsystemsleakandifhosesarebrokentheycansprayhydraulicfluidthroughoutthesteelplant.
Infactthissituationworsenswiththeageofthesystem.Inthiscase,itislikelythatthehydraulicsystemislocatedneareitheranakedflameorahotormoltenmetal.High-pressuremineralhydraulicfluidcancomeincontactwiththoseignitionsourcesandthepotentialforafireisthenpresent.
Fire-resistanthydraulicfluidsarethereforeessentialforthesafe,cost-effectiveoperationofmajorcomponentsofsteelproduction.Thistechnicalsupportmanualisprimarilyfocusedonpolyolesterhydraulicfluids,suchasCastrolAnvolSWX,butalsodoesreferenceotherfireresistanthydraulicfluids.
Thepurposeofthistechnicalsupportmanualistoallowsteelengineerstomakequalifieddecisionsaboutthefireresistanthydraulicfluidtheyuseandassisttheminconsideringotherfactorssuchassystemcompatibility,fluidconditionmonitoringandfluidtrialing,plusappropriatefluidchangeoverprocedures.
Theaimistoprovideyouwithabest-in-classfireresistanthydraulicfluidwhichoffersoptimumfireprotection,premiumsystemprotectionandextendedsystemlife.
Backgroundcontinued
Firesinmetalmanufacturingplantsarenotathingofthepast.Infact,accordingtoFactoryMutual(seeSection2),astudyoflossesintheUnitedStatesbetween1981and1990showedthat134firesoccurredinvolvinghydraulicfluids,resultinginmillionsofdollarsinlosses.Nearlyhalfoftheselossesoccurredinmetalworkingprocesses,suchasmachineshops,rollingmills,orheat-treatmentshops.
Primemotivatorsfortheuseoffire-resistanthydraulicfluidsaresafetyconsiderationsandinsuranceguidelines.Firesafetypoliciesandproceduresprotectbothpeopleandequipment.Insurancecompaniesprovideincentivesintheformofreducedpolicycostsforcompaniesthatmeetsetstandards.
ThisisstillarealissuewithmanyofoursteelcustomersandneedstobeincorporatedintodiscussionswehavewhenwetalkaboutHealth,Safety,SecurityandtheEnvironment(HSSE).
Changestothewayproductsareevaluatedforfireresistancehaveoccurredoverthelastfewyears.FactoryMutual,theprimaryinsuranceunderwriterthattests,certifiesandsetsstandardsforsafeuseofequipmentandproducts,hasadjusteditsfire-resistancefluidsrankingscale,makingitmorerestrictive.EffectiveJuly1,2003,twonewproductclassifications–Group0andGroup1–willbeinsertedintotheclassificationtableinthenewstandard#6930.ThiswillbediscussedinfullwithinSection2.
Customershaveanumberofwaystominimizeriskswhentacklingtheissueoffiresemanatingfromhydraulicfluids.TheycaneitherstaywithlowperformingfireresistanthydraulicfluidssuchasGroup2(seeSection2fordetails)andinstallexpensivefiresuppressionequipmentortheycanelecttouseanappropriatefireresistanthydraulicfluidfromtheGroup0orGroup1category.WhichfluidtochooseforyourspecificapplicationcanbefoundinSection2.Generallythereisatrade-offbetweenfireresistanceperformanceandhydraulicsystemperformance.Anextremeexampleofthisistheuseofwater.Ithasexcellentfireresistanceproperties,howeveritsabilitytoprotectconventionalpumpsagainstwearisextremelypoor.
Thereisnotonlyatrade-offbetweenfireprotectionandsystemperformanceamongdifferentfamiliesofhydraulicfluids,(e.g.HFAversusHFDU)butalsowithinfamilies.Notallpolyolestersperformequallyinhydraulicsystems.Infacttherehasbeenalonghistoryofheavysludgeandvarnishformationwithinsomebrandsofproducts.Itisessentialwhendesigningtheseproductsthattheyareformulatedtomeetthehigheststandardsexpectedbyconventionalcirculatoryoils.Manyinternationalstandardshavebeenwrittentoobjectivelyandquantitativelyevaluateaproductforitssuitabilityinahydraulicsystem.AnexampleofthisisAmericanSocietyofTestingMethodD943.Effectivelyratingcomparativeperformanceofhydraulicfluidsinsystems,thismethodallowsengineerstocompareoneproductagainstanothertodeterminetheeffecttheywillhaveoncriticalcomponentssuchasvalves,withregardtovarnishingand,importantlyhowlong,comparatively,theproductwilllastinasystem.
AdetailedanalysisispresentedinSection4comparingthesystemreliabilityofCastrolAnvolSWXversusawell-knowncompetitor.
Ratingmethodsforfireresistanthydraulicfluidsandfluidselection
Therearemanyinternationallyrecognizedstandardsthatratehydraulicfluidsfortheirpotentialtoresistburning.Thetwomostcommonmethodsarethe7thLuxembourgReportandthosedesignedbyFactoryMutual.Inthesteelandmanufacturingindustries,FactoryMutualisarguablythemostwell-known.
FactoryMutual
FactoryMutualisalargeprimaryinsuranceunderwriter,basedinNorwoodMAnearBostonUSA.Theyhavehadalongassociationwithinsuringheavyindustrystartingwithtextileplantsandmovingintometalmanufacturingsuchassteel.ForfurtherinformationonFactoryMutual,visittheirwebsiteat.
Theyrealizedearly-onthatalargenumberoftheirclaimswerecomingfromfiresthatinvolvedhydraulicfluidleakage.Tohelpminimizetheriskattheplantandhencethepropensityformakinginsuranceclaims,FactoryMutualdidtwothings.First,theywouldadvisecustomersonstepstotaketoreducetherisksoffiredamageandthenauditthemtoensurethosestepsweretaken.Second,theirengineeringdepartmentdevisedawayofevaluatingfluidsforacategorycalled“LessHazardousFluids”.Thesefluidswereconsideredsufficientlyfireresistanttouseinhazardousmanufacturingenvironments.
Thiswasaqualitativemethodfordeterminingproductsthatcouldpasstwovisualtestswhichwere:
1)SprayFlammabilitytest
2)HotManifoldtest
Thesetwotestsweredesignedtosimulatethetwomostcommoncausesoffire.First,whenhigh-pressurehydraulicfluidescapesfromahoseandhitsaflameorignitionsource(SprayFlammabilitytest)andsecondwhenhydraulicfluidpoolsontoahotsurface(HotManifoldtest).
Ratingmethodscontinued
Inordertosuccessfullypassthesprayflammabilitytest,fluidsupplierswouldcommonlyresorttoaddingpolymertotheirpolyolesterfluidstohelpincreasethesizeofthefluiddroplets(reclassify)asthefluidbecameatomizedafterleavingthespraynozzle.Theideabehindthatwaswhentheatomizedfluidhittheignitionflameinthetest,theflamegeneratedbythepolyolesterwouldstandabetterchanceofselfextinguishingaftertheignitionflamewasremovedifitsatomizeddropletswerelargenotsmall.Thefluidalsohadtopassthehotchanneltestandonceithaddonethisitwasgivenapassorfail.A“pass”wasconsideredtobea“LessHazardousFluid”.
Theonlydraw-backtothatwasthatthepolymerscommonlyusedforthis,sheardowninuseandeffectivelylosetheirabilitytoreclassifythepolyolesterdroplets.Thenetresultofthiswasthatafterashortperiodoftimeinthehydraulicsystem,thefluidwouldnolongerpassthestandardFactoryMutualtest.Notonlythat,theviscosityoftheproductdecreasedbyasmuchas15%asdemonstratedinFigure1.
CastrolAnvolSWX
Section2
Forinternaluseonly
Figure1
Thisfactanddatacollectedovertheperiodof1981to1990showedthattherewerestillmanyfluidsinvolvedinfires.Infact,manyfluidstestedfromthefieldshowedenormousvariabilityintheirfireprotectionproperties.ThispromptedthemtodeviseanewmethodofevaluationunderthenewFactoryMutualclassificationstandard#6930.CastrolAnvolSWXwasspecificallydesignedtoconformtothisnewstandard,providingsteelengineerswithasaferoptionwhenselectingtheirfireresistanthydraulicfluid.
NewFactoryMutualstandard-#6930
Thenewstandardwasfirstpublishedforreviewin1991.Ittakesadifferentapproachtothepreviousmethodbyassessingafluidthroughaquantitativemeansandnotaqualitativeone.Thereforefluidscanberatedandcategorizedintogroups.Theyhavedonethisbyusingathermodynamiccalculationtoeffectivelyratefluidsontheirabilitytobothcatchfireandsustainafire.
ThevaluethattheycalculateiscalledtheSprayFlammabilityParameterrepresentedbythefollowingcalculation:
SFP=8.31X106XQch/(pfqcrmf)
Where:
Qch=ChemicalHeatReleaseRate
pf=densityofthefluid
=CriticalHeatFluxforIgnition
qcr
BasicallytheChemicalHeatReleaseRatedeterminestheamountofheatreleasedwhenthefluidisburnt.Thisisimportantasitdetermineshowlikelyafluidistosustainafireoncethefluidhasbeenignited.ThepieceofequipmentthatisusedtomeasurethisheatreleaserateisillustratedinFigure2.
Figure2
NewFactoryMutualstandardcontinued
TheCriticalHeatFlux
- 配套讲稿: