DD670更换硬盘
EMCDD670更换硬盘
ReplacingaStorageDrive
PreparingfortheProcedure
Caution:
Wearananti-staticwriststrapattachedtoanunpaintedmetalsurfaceontherackorchassiswhenhandlingparts。
Caution:
Onlytrainedcustomerpersonnelshouldperformthisprocedure。
1.Ifnecessary,initiateanincidentasdescribedinInitiatinganIncident。
2.ObtainareplacementpartasdescribedinObtainingaReplacementPart。
3.ContactthesystemadministratorifyoudonotknowthehostnameorIPaddressoftheSOV-enabledCMIC。
4.Removethenewpartfromitspackagingandplaceitonastatic-freesurface。
5.Recordtheserialnumberand/orpartnumberofthenewpartinthesiteequipmentlog。
6.Usingabrowser,connecttotheServerManagementWebServicesHomepagebytypingthefollowingintheAddressfieldofthebrowser:
http:
//
9980/CWA/home。
asp
7.OntheServerManagementWebServicesHomepage,clickServerManagementClient。
8.Ifprompted,logontoServerManagementClientasaServiceUser。
TheServerManagementClientsoftwareopens。
9.IftheSummaryAlertViewerwindowisnotalreadyopen,openitbyselectingWindow>SummaryAlertViewe。
IntheSummaryAlertViewerwindow,theSynopsisfieldindicateswhichdrivehasfailed。
ThefollowingDriveFailureSummaryAlertsareavailableforcustomerreplacement:
•ProactiveArrayDriveReplacementrequired,inDRIVE。
x.x.x.x.x
•ArrayDriveFailurewithGHScoverage,inDRIVE。
x.x.x.x.x.x
•ArrayDriveFailurewithoutGHScoverage,inDRIVE。
x.x.x.x.x
•ArrayDriveFailure,inDRIVE。
x.x.x.x.x.x
10.IntheTreeView,selectthediskarraythatcontainsthefaileddrive。
Note:
Awarningmessageappearsnexttothediskarraywiththefaileddrive。
Figure3:
TreeViewwithaFailedDrive
11.OpenaMaintenanceWindow。
ThispreventsalertsfrombeingforwardedtoTeradataServicesatsitesthatareTVI-connected。
a)SelectFunctions>MaintenanceWindow。
AMaintenanceWindowdialogboxappears。
Figure4:
MaintenanceWindowDialogBox
b)IntheMaintenanceDurationfield,settheStartTimeandtheEndTime。
StartTimeisthedateandtimetheMaintenanceWindowopens,andEndTimeisthedateandtimetheMaintenanceWindowcloses;thedefaultisfourhours。
c)AtName,enteranamefortheMaintenanceWindow。
Note:
Ifyouwanttosetotheroptionsinthiswindow,seetheonlinehelpforinstructions。
d)ClickActivate。
e)IntheInformationdialogboxthatappears,clickOKtoacknowledgethe
maintenancewindowhasbeensaved。
Ifmoretimeisneededtocompletetheprocedure,extendthedurationoftheopenmaintenancewindowbychangingthenumberofhoursintheMaintenanceDurationfieldandclickActivate。
12.SelectFunctions>ReplaceFRU。
13.WhentheReplaceFRUdialogboxappears,selectChassisComponent,thenclickOK。
14.Selectthetraythatcontainsthefaileddiskdrive。
IntheDiskArraywindowthatappears,theFrontViewpanelshowsarediconnexttothefaileddiskarray。
15.IntheDiskArraywindow,selectFrontView。
Figure5:
DiskArrayFrontViewPanelwithaRedIconIndicatingtheFailedDiskDrive
16.IntheDiskArrayFrontViewwindowthatappears,selectthenumberedrediconidentifyingthefaileddiskdrive。
Figure6:
DiskArrayFrontViewWindowIndicatingtheNumberedFailedDrive
TheFRUReplacewindowappears。
17.Verifythatthediskarraydriveisreadyforservicing。
Figure7:
DiskArrayDriveReplaceProcedure
a)Attherearofthecabinet,openthecabinetdoor。
b)VerifytheblueServiceActionAllowedLEDonthetargetdriveisilluminated。
•IftheblueServiceActionAllowedLEDonthetargetdriveisilluminated,returntotheFRUReplacewindowandclickOk。
•IftheblueServiceActionAllowedLEDonthetargetdriveisnotilluminated,returntotheFRUReplacewindowandclickCancel。
Note:
Ifanyproblemsareencountered,notifyTeradatacustomerservices。
Useacontactmethodthatisinaccordancewithyourservicecontract(forexample,initiateorupdateanincidentthroughTeradata@YourService)。
18.ClickOktoadvancetothereplacementstep。
Thesoftwarechecksthedrivestatusandverifiesthatallconditionsforreplacingthedrivehavebeenmet。
Note:
Ifanyproblemsareencountered,notifyTeradatacustomerservices。
Useacontactmethodthatisinaccordancewithyourservicecontract(forexample,initiateorupdateanincidentthroughTeradata@YourService)。
RemovingaStorageDrive
Figure8:
RemovingaStorageDrive
1.Atthefrontofthecabinet,locatethedriveenclosurewiththeamberServiceActionRequiredLED。
2.LocatethestoragedrivewithamberServiceActionRequiredandblueServiceActionAllowedLEDs。
TheServiceActionAllowedLEDindicatesthatthemodulecanbesafelyserviced。
3.Pressthelatchreleasebutton,openthelatch,andslidethedriveoutoftheenclosure。
Note:
Afterremovingthefailedstoragedrive,waitaminimumof30secondsbeforeinstallingthenewdrive。
4.ReturntoServerManagementClientand,intheFRUReplacewindow,clickOk。
InstallingaStorageDrive
Caution:
Wheninstallingareplacementdrive,ensurethatthereplacementdriveisforeigntothearray。
Donotuseaglobalhotspare(GHS)drivefromthesamearray。
Caution:
IfthereplacementdriveisFDE-enabled(containsalockkey),itmustbereprovisioned(secureerased)beforeitcanbeintegratedintoavolume。
Figure9:
InstallingaStorageDrive
1.Openthedrivelatchandinsertthenewdriveintotheemptydrivebay。
2.Pushthedriveinuntilitisfirmlyseated。
3.Closethedrivelatchandpressfirmlyuntilaclickisheard。
AstheHDDspinsup,thedrive'sServiceActionRequiredLEDmightblinkintermittently。
AblinkingActiveLEDindicatesthatdataisbeingrestoredtothenewdrive。
4.Refertothetablebelowforinstructionsonhowtoproceed。
ReprovisioningStorageDrives
Caution:
Onceadriveisreprovisioned,thedatacannotberecovered。
Note:
ThisprocedureisperformedonlywhenanFDE-enableddriveisinstalledasareplacementforafaileddrive。
OnlyHDDscanbeFDE-enabled。
1.ToaccessSYMplicityonanSWS,performoneofthefollowing,dependingonyoursystemconfiguration:
2.FromtheSWSdesktop,clickTools>SYMclient。
SYMplicityStorageManagersoftwareopens。
3.Highlightthearraycontainingthedrivetobereplaced,thenselectTools>ManageStorageArray。
4.ClickthePhysicaltab。
5.Right-clicktheiconforthedrivethatneedstobereplaced,thenselectSecureErase。
Aconfirmationwindowappears。
6.TypeYes,thenselectOK.
CompletingtheProcedure
1.IntheMaintenanceWindow,clickDelete。
2.ReturntoServerManagementClientand,intheFRUReplacewindow,clickOK。
Thestoragearrayautomaticallyrestoresdatatothenewdrive。
YoucanmonitordrivereconstructionfromServerManagementClient。
Note:
Ifanyproblemsareencountered,notifyTeradatacustomerservices。
Useacontactmethodthatisinaccordancewithyourservicecontract(forexample,initiateorupdateanincidentthroughTeradata@YourService)。
3.WhentheReplaceFRUconfirmationdialogboxappears,clickOKtoclosetheFRUreplacementsessioninServerManagementClient。