VxRail超融合平台软件更新手册.docx
- 文档编号:4332400
- 上传时间:2022-11-29
- 格式:DOCX
- 页数:31
- 大小:3.26MB
VxRail超融合平台软件更新手册.docx
《VxRail超融合平台软件更新手册.docx》由会员分享,可在线阅读,更多相关《VxRail超融合平台软件更新手册.docx(31页珍藏版)》请在冰豆网上搜索。
VxRail超融合平台软件更新手册
VxRail超融合平台软件更新手册
Topic
VxRailGen2ApplianceSoftwareUpgradeProcedure
Selections
Selectthecodelevel:
VxRailv4.0.100
ServiceProvider:
EMC
Service_Provider_Project_Cust_info.doc
ServiceProvider,ProjectInformationandCustomerContactform
ThisformisautomaticallypopulatedbasedontheinformationthatisprovidedintheVxRail®ProcedureGeneratorquestionnairepriortogeneratingtheprocedure.Thisinformationiscollectedandusedforreferencepurposeswhenreferringbacktothisprocedureatalaterdateandtime.
Section1:
ServiceProviderInformation
Whatisyourname:
Whatisyouremailaddress:
Section2:
EMCProjectInformation
EMCCSISR#:
EMCProject/PASID(orPartnerCompanyName):
Section3:
CustomerAccountInformation
CustomerSiteName:
CustomerContactName:
CustomerSiteStreetAddress:
CustomerSiteCity:
CustomerSiteState/Country:
Warning_DL.doc
WARNING:
DATALOSS!
WARNING:
Thisprocedureisdestructive.
Ifthereisanydataonthesystemthatthecustomerneeds,itmustbebackedupormigratedoffthesystempriortoperformingthisprocedure.
VxRail_Nicias4_0_100_Mobile_Build_Server_Setup.doc
VxRailv4.0.100MobileBuildServerSetup
Task 1:
VerifyBuildSystemComponents
Verifyyouhaveaccesstothefollowingbuildsystemcomponents:
Aportableserverorlaptopwiththefollowingcharacteristics:
CPU:
2coresthatsupportvirtualizationtechnology
Memory:
Atleast8GBRAM
Disk:
Atleast70GBoffreediskspace
Network:
1NIC,1dedicated1GbEthernetSwitchand4GBICadapters
A64-bitoperatingsystemthatsupportsatleastversion10ofVMwareWorkstation
∙Accesstotheinstallimageforversion10orlaterofVMWareworkstationversion10orlater.
VMwareWorkstationcanbeobtainedviaEMC’sELAwithVMware.LicensescanbeorderedthroughART.
∙AccesstotheEMCOnlineSupportsitefordownloadoftheVxRailBuildServervirtualapplianceandsoftwareimages.
Task 2:
InstallVMwareWorkstation
11. [ ]DownloadandInstallVMwareWorkstationversion10orlater.
Figure 1VMwareWorkstationSetup
Figure 2VMwareWorkstationSetup–LicenseAgreement
Figure 3VMwareWorkstationSetup–SetupType
Figure 4VMwareWorkstationSetup–DestinationFolder
Figure 5VMwareWorkstationSetup–SoftwareUpdates
Figure 6VMwareWorkstationSetup–UserExperience
Figure 7VMwareWorkstationSetup–Shortcuts
Figure 8VMwareWorkstationSetup–ReadytoPerformRequestedOperations
Figure 9VMwareWorkstationSetup–LicenseKey
Task 3:
DisableFirewall
DisabletheFirewallonyourlaptop.IfthelaptophasMcAfeeinstalledonit,disabletheFirewallasfollows:
21. [ ]LocatetheMcAfeeicon.
22. [ ]Right-click,gotoQuickSettings.
23. [ ]DisableFirewall.
Figure 10DisableFirewall
Task 4:
EnableSettingIPAddressAutomatically
31. [ ]FortheConnectionportthatisconnectedtothededicated/internalbuildswitch,ensurethatIPV4issettotheObtainanIPaddressautomatically.
Figure 11TCP/IPProperties
Task 5:
ConfigureWorkstationvirtualnetwork
TheVxRailBuildServerisavirtualappliancethatwillusethevirtualnetworksconfiguredinVMwareWorkstationtocommunicatewiththeVxRailappliancenodes.ThevirtualnetworkmustbeconfiguredbeforedeployingtheVxRailBuildServervirtualappliance.
41. [ ]AccesstheVirtualNetworkEditorfromtheVMwareWorkstationmainmenu.
Figure 12VMwareWorkstation–EditàVirtualNetworkEditor
42. [ ]RemovethedefaultVMnet0,VMnet1andVMnet8networks
Figure 13VirtualNetworkEditor
43. [ ]AddVMnet10forBuildServerconnectivity.
Figure 14Select'AddNetwork'
Figure 15Select'VMnet10'
Figure 16SetpropertiesforVMnet10
44. [ ]SetthefollowingpropertiesforVMnet10:
ModifytheVMNet10settingtoNAT
Uncheck“UselocalDNS…”
SetupthesubnetIPto“192.168.254.0”.
45. [ ]AddVMnetVMnet11toenablebridgedconnectivity.SetVMnet11toBridgedtoenableconnectivitytothephysicalEthernetconnectionNIC.ThisNICwillbeconnectedtothededicatedEthernetswitch.
Figure 17ConfigureBridgedvirtualnetwork
Figure 18WorkstationVirtualNetworkFinalSettings
Task 6:
DownloadVxRailsoftwarepackages
51. [ ]TheVxRailupdatepackageswillconsistoftheBuildServervirtualappliancearchive,andtheVxRailsoftwareupdateimages.Packagesmaybedownloadedfromandunzippedtoalocaldirectory.
PackageVersion
MD5Checksum
v4.0.100_golden_image.zip
39771828825f093fd80e4bcae1d4f366
v4.0.100_build_system.zip
f72089942c1438d3dcfde0cf0281bac6
Task 7:
EnsureYourSystemTimeisAccurate
61. [ ]DisabletheFirewallonyourlaptop.IfthelaptophasMcAfeeinstalledonit,disabletheFirewallasfollows:
62. [ ]Ontherightcornerofthescreen,clickthetime,andclick“Changedateandtimesettings…“
Figure 19ChangeDataandTimeSettings
63. [ ]Inthe“DateandTime”dialog,ensurethetimeiscorrectregardingtothetimezone.
Figure 20DataandTime
64. [ ]Ifnot,changethetimetothecorrecttime/timezone.
Note:
Thetimezonedoesnotrequiredtobesetthesameaslocal,butthecurrenttimeregardingtothetimezonemustbesetcorrectly.
Task 8:
DeployVxRailBuildServerVirtualAppliance
TheBuildServerisaVMwarevirtualappliance.Deploythevirtualmachinefromthevirtualmachinearchivefile.
71. [ ]LocatetheBuildServervirtualappliance.ThefileisinOVAformat.
72. [ ]DeployBuildServervirtualapplianceonVMWareWorkstation.
ClickFile
Open,andbrowsetotheBuildSystemVMpackage.
Then,followtheinstructionbelowtoimportVM.
Figure 21ImportVirtualMachine
Figure 22ImportingVirtualMachine
73. [ ]Right-clickthejustdeployedVMandselectSettings….
Figure 23EditSettings
74. [ ]ModifyMemoryforthisvirtualmachinetoatleast4096.
Figure 24VirtualMachineSettings
75. [ ]Configurevirtualmachinenetworksettings:
TheBuildServerVMisconfiguredwithsixNetworkAdapters(1to6).InthiscustomizedBuildServersetup,onlytwoNetworkAdapter1-2willbeused.
a.ClickonEditVirtualMachineSettings.
b.MapeachNetworkAdapterasfollows:
NetworkAdapter1-VMNet10,Checkbox“ConnectatPoweron”
NetworkAdapter2-VMNet11,Checkbox“ConnectatPoweron”
NetworkAdapter3-HostOnly,Uncheckbox“ConnectatPoweron”
NetworkAdapter4-HostOnly,Uncheckbox“ConnectatPoweron”
NetworkAdapter5-HostOnly,Uncheckbox“ConnectatPoweron”
NetworkAdapter6-HostOnly,Uncheckbox“ConnectatPoweron”
Figure 25SetVirtualNetworkAdaptertoVMnet10
Figure 26SetvirtualnetworkadaptertoVMnet11
Figure 27FinalVMNetworkSettings
76. [ ]PoweronandtestBuildServervirtualmachine.
Figure 28BuildServerPower-on
c.TheBuildServerhasastaticIPaddressof192.168.254.20.CheckLinuxvirtualmachinenetworkandbuildnetworkconnectionsforthefollowingIPs.
ping192.168.254.20
ping192.168.252.252
Task 9:
UploadVxRailv4.0.100softwareupdateimagetoBuildServer
TheBuildServerisaLinux-basedvirtualmachineaccessiblebywebbrowser.ThewebinterfaceisusedtouploadtheVxRailsoftwareimagestotheBuildServer.Thesoftwarethatwillbeloadedintotheappliancesisallbundledasonepackage.Thepartnumberofthispackageis992-720-600.LoadtheImagebundleintothebuildserverforprovisionanappliancewithfollowingsteps.
11. [ ]LaunchaBuildServerbrowsertohttp:
//192.168.254.20andenablesystemconfiguration
Figure 29EnableBuildServerSystemConfiguration
12. [ ]UploadthegoldenimagetothebuildserverVM.
d.Fromtheconfigurationinterface,click“Clicktouploadgoldenimage”
Figure 30Uploadupgradepackage
e.Browsetothegoldenimagepackage,selectthefile,andwaitforimporttofinish
f.Aftertheimportcompletes,ClicktheBluebannerthatsays:
“Clicktoinstallpackage”
13. [ ]Uploadtheupgradepackage
g.Fromtheconfigurationinterface,click“Clicktouploadaupgradepackage”.Browsetothelocationwherethe“UpgradeImagePackage”islocated,selectthefile,andwaitforimporttofinish.
Figure 31FileSelection
Figure 32GoldenImageFileimport
Figure 33BuildServerreadyforusage
h.Oncetheuploadiscomplete,amessagewillpopupandthesystemisreadyforupgradingVxRailappliances.
VxRail_Nicias_Appliance_MBS_Cable_Gen2.doc
VxRailGen2Appliancev4.0.xSoftwareImageInstallationUsingMobileBuildServer.
Overview
ThisguideprovidesinstructionsonhowtouploadanewversionoftheVxRailsoftwareimagetoaVxRailGen2appliance.Thisprocessusesamobilebuildserver,whichisaportablevirtualmachinethatrunsonalaptopusingVMwareWorkstation(Windows)orVMwareFusion(Mac).ThebuildservercontainstheVxRailsoftwareimage,andthecodeinstructionstouploadtheimagetoeachnode.ThisprocessrequiresdedicatedandisolatednetworkconnectivitybetweenthebuildserverandeachoftheVxRailnodesintheappliance.
WARNING:
ThisProcedureisdestructiveandwillpermenantlyerasealldataontheappliance.PriortousingthisproceduretoupgradeanVxRailAppliance,Allcustomerdatamustbebackedupormigrationofftheappliance.
Thisprocessincludesthesemajormilestonesinordertoassureasuccessfulupgrade:
91. [ ]Alltheplanningandpreparationstepsarecompletedbeforeperformingtheupgrade.
92. [ ]Physicalnetworkconnectivityisestablishedbetweenthe‘uildServerandalloftheVxRailnodes.
93. [ ]ConnectivitytotheBuildServerwebinterfaceisestablished.
94. [ ]TheVxRailsoftwareupdatecompletessuccessfully.
95. [ ]TheupdatedVxRailapplianceisre-configured.
Task 10:
Verifyallrequiredpre-requisite
- 配套讲稿: