FCC报告模板
TESTREPORT
ApplicantName&Address
:
SpecializedMesengerServices
836JuryCourt,Suite10SanJose,CA95112,USA
ManufacturerName&Address
:
FoshanShundeLoskonElectricCo.,ltd
No.22RenminRoadLunjiao,Shunde,Foshan
Product
:
PowerAmplifier
ModelNo.
:
R-70a,R-80,R-1050
ElectricalRating
:
AC120V,60Hz
COUNTRYOFORIGIN
:
CHINA
DateReceived
:
2011-10-17
DateTestConducted
:
2011-10-17to2011-10-21
Teststandards
:
FCCPart15,ClassB:
2009
TestResult
:
Pass
Conclusion
:
Thesubmittedsamplescompliedwiththeaboverules/standards.
Remark
:
Partnumber:
153633.001
***************************************EndofPage***************************************
PreparedandCheckedBy:
ApprovedBy:
_______________________Signature
FvanTuStevenZhou
EngineerTeamLeader
GTSGuangzhouGTSGuangzhou
2011-10-21Date
ThisreportisfortheexclusiveuseofGTS'sClientandisprovidedpursuanttotheagreementbetweenGTSanditsClient.GTS'sresponsibilityandliabilityarelimitedtothetermsandconditionsoftheagreement.GTSassumesnoliabilitytoanyparty,otherthantotheClientinaccordancewiththeagreement,foranyloss,expenseordamageoccasionedbytheuseofthisreport.OnlytheClientisauthorizedtopermitcopyingordistributionofthisreportandthenonlyinitsentirety.AnyuseoftheGTSnameoroneofitsmarksforthesaleoradvertisementofthetestedmaterial,productorservicemustfirstbeapprovedinwritingbyGTS.Theobservationsandtestresultsinthisreportarerelevantonlytothesampletested.Thisreportbyitselfdoesnotimplythatthematerial,product,orserviceisorhaseverbeenunderanGTScertificationprogram.
Thetestreportonlyallowstoberevisedwithinthreeyearsfromitsoriginalissueddateunlessfurtherstandardortherequirementwasnoticed.
GeneralTestingServicesCo.,Ltd
5F-20ofXiangpuBuilding,XiangpuStreet, DongpuTown,GuangzhouCity,Guangdong,China
Tel/Fax:
86-20-62359071/86-20-22227157
CONTENT
1TESTRESULTSSUMMARY
ClassificationofEUT:
ClassB
TestItem
Standard
Result
ConductedEmission
FCCPart15,ClassB:
2009
Pass
RadiatedEmission
FCCPart15,ClassB:
2009
Pass
Remark:
1.Whendeterminingthetestresults,measurementuncertaintyoftestshasbeenconsidered.
2.Whendeterminingthetestresults,measurementuncertaintyoftestshasbeenconsidered.
2
TestResultsConclusion
(withJustification)
RE:
EMCTestingPursuanttoFCCPart15,ClassB:
2009PerformedOnthePowerAmplifier,
Models:
R-70a
WetestedthePowerAmplifier,Model:
R-70atodetermineifitwasincompliancewiththerelevantFCCrulesasmarkedontheTestResultsSummary.WefoundthattheunitmettherequirementofFCCPart15,ClassB:
2009whentestedasreceived.Theworstcase’stestdatawaspresentedinthistestreport.RadiatedemissionwastestedinGeneralTestingServices.
Conclusion:
ThesampleasreceivedcompliedwiththeFCCPart15requirement.
ThetestresultsofdigitaldeviceportioninFCCtestreportaredeemedsatisfactoryevidenceofcompliancewithIndustryCanadaInterference–CausingEquipmentStandardICES-003.
Theproductionunitsarerequiredtoconformtotheinitialsampleasreceivedwhentheunitsareplacedonthemarket.
3LABORATORYMEASUREMENTS
ConfigurationInformation
EquipmentUnderTest(EUT):
CUTTLEFISH
Model:
R-70a
SerialNo.NotLabelled
SupportEquipment:
N/A
RatedVoltage:
AC120V
ConditionofEnvironment:
Temperature:
15~35C
RelativeHumidity:
35~60%
AtmospherePressure86~106kPa
Notes:
1.EUTGrounding
Theunitwasgroundedasnormallyused.
2.TestEnvironment
Ifambientlevelsofemissionsexceedtheappropriatelimit,thefollowingstepsweretakentoassurecompliance.First,themeasurementbandwidthwasreduced,ifthisdidnotaffectthepeakreadings.Suchareductioncanallowmuchcloserexaminationofemissionsclosetolocalambientsignals.Second,theantennacouldbebroughtclosertotheEUT.Finally,inseverecases,testingwasreperformedatnightorothertimeswhentheoffendingsignalwasofftheair.Themeasurementsweremadeatnominalroomtemperature(25oC±10oC).
3.TestSite
ConductedEmissiontestwasdoneinShieldingRoomofGTS.RadiatedEmissiontestwassubcontractedandwasdonein3msemi-anechoicchamber.
4.TestPlatform
Radiatedemissiontestwasmadeon0.8mhigh,1mx1.5mwidenonconductiveplatform.Conductedemissiontestwasmadeon0.4mhighnon-metallictableaboveearthedgroundplane(GroundReferencePlane).TheEUTkeepsadistanceofatleast0.8mfromanyotherofthemetallicsurface.
5.MeasurementUncertainty
Whendeterminingofthetestconclusion,theMeasurementUncertaintyoftesthasbeenconsidered.
4
TESTRESULTS
4.1ConductedEmissionTest
TestResult:
Pass
4.1.1UsedTestEquipment
TestEquipment
Manufacturer
Model
SerialNo.
LastCal.
Cal.Due
EMITestreceiver
R&S
ESCI
CTS-102
2011/04/16
2012/04/16
Two-linev-network
R&S
ENV216
CTS-103
2011/03/16
2012/03/16
ShieldedRoom
ETS•Lindgren
8*4*3
CTS-101
2009/03/13
2012/03/12
4.1.2BlockDiagramofTestSetup
4.1.3TestSetupandProcedure
1.Themainsterminaldisturbancevoltagetestwasconductedinashieldedroom.
2.TheEUTwasconnectedtonominalpowersupplythroughaLISN1(LineImpedanceStabilization
Network)whichprovidesa50Ω/50μH+5Ωlinearimpedance.Thepowercablesofallotherunitsof
theEUTwereconnectedtoasecondLISN2,whichwasbondedtothegroundreferenceplanein
thesamewayastheLISN1fortheunitbeingmeasured.Amultiplesocketoutletstripwasusedto
connectmultiplepowercablestoasingleLISNprovidedtheratingoftheLISNwasnotexceeded.
3.ThetabletopEUTwasplaceduponanon-metallictable0.8mabovethegroundreferenceplane.
Andforfloor-standingarrangement,theEUTwasplacedonthehorizontalgroundreferenceplane,
butseparatedfrommetalliccontactwiththegroundreferenceplaneby0.1mofinsulation.
4.Thetestwasperformedwithaverticalgroundreferenceplane.TherearoftheEUTshallbe0.4mfromtheverticalgroundreferenceplane.Theverticalgroundreferenceplanewasbondedtothehorizontalgroundreferenceplane.TheLISN1wasplaced0.8mfromtheboundaryoftheunitundertestandbondedtoagroundreferenceplaneforLISNsmountedontopofthegroundreferenceplane.ThisdistancewasbetweentheclosestpointsoftheLISN1andtheEUT.AllotherunitsoftheEUTandassociatedequipmentwasatleast0.8mfromtheLISN2.
4.1.4TestData
Pre-scanwasperformedwithpeakdetectedonbothliveandneutralcable.Quasi-peak&averagemeasurementswereperformedatthefrequencieswhichmaximumpeakemissionlevelwasdetected.PleaseseetheattachedQuasi-peakandAveragetestresults.
4.1.5TestCurve
Model:
R-70a
LiveLine:
PeakScan:
Level(dBμV)
Quasi-peakandAveragemeasurement
NeutralLine:
PeakScan:
Level(dBμV)
Quasi-peakandAveragemeasurement
4.2RadiatedEmission
TestResult:
Pass
4.2.1UsedTestEquipment
Description
Manufacturer
ModelNo.
SerialNo.
EMIReceiver
R&S
ESCI
SZ185-01
BiconilogAntenna
ETS
3142C
SZ061-04
RFCable
RADIALL
RG213U
SZ062-01
AnechoicChamber
ETS
RFD-F/A-100
SZ188-01
4.2.2BlockDiagramofTestSetup
4.2.3TestSetupandProcedure
Themeasurementwasappliedina3msemi-anechoicchamber.TheEUTandsimulatorswereplacedona0.8mhighwoodenturntableabovethehorizontalmetalgroundplane.Theturntablerotated360degreestodeterminethepositionofthemaximumemissionlevel.TheEUTwasset3metersawayfromthereceivingantennawhichwasmountedonanantennamask.Theantennamovedupanddownbetweenfrom1meterto4meterstofindoutthemaximumemissionlevel.
Broadbandantennawasusedasreceivingantenna.Bothhorizontalandverticalpolarizationoftheantennawassetonmeasurement.Inordertofindthemaximumemission,alloftheinterfacecablesweremanipulatedaccordingtoANSIC63.4:
2003requirementduringradiatedtest.ThebandwidthsettingonR&STestReceiverwas120kHz.Thefrequencyrangefrom30MHzto1000MHzwaschecked
4.2.4TestData
OperationModel:
EUTon
4.2.5TestCurve
Horizontal
Vertical
4.2.6Measurementuncertainty
Uncertainty:
4.8dBinthefrequencyrangeof30-1000MHzatalevelofconfidenceof95%.
5AppendixI-Photosoftestsetup
RadiatedEmission
6AppendixⅡ-PhotosofEUT
FCCLABELLINGAND
INSTRUCTIONMANUALREQUIREMENTS
DevicessubjecttoFCCPart15,ClassBverification(notcertification)mustbelabelledwiththefollowingstatement.Thelabelcanbeaffixedatanyspaceexternaltotheproductexceptthebatterydoorordetachableparts.
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:
(1)thisdevicemaynotcauseharmfulinterference,and
(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.
Inaddition,foraClassBdigitaldeviceorperipheral,theinstructionsfurnishedtheusershallincludethefollowingorsimilarstatement,placedinaprominentlocationinthetextofthemanual:
Warning:
Changesormodificationstothisunitnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser'sauthoritytooperatetheequipment.
NOTE:
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionaga
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FCC 报告 模板