BAS系统主要监控原理
BAS系统主要监控原理
BAS系统监控原理......................................................................................................................1
1、空调机组监控............................................................................................................................2
1.1监控内容........................................................................................................................2
1.2控制方案........................................................................................................................2
1.3启动顺序........................................................................................................................3
2、新风系统监控............................................................................................................................4
2.1监控内容:
....................................................................................................................4
2.2控制方案:
....................................................................................................................4
2.3启停顺序:
....................................................................................................................5
3、冷热源系统监控........................................................................................................................6
3.1监控内容:
....................................................................................................................6
3.2控制方案:
....................................................................................................................7
3.3启停顺序:
....................................................................................................................8
4、公共照明系统监控.....................................................................................................................9
4.1监控内容:
....................................................................................................................9
4.2控制方案:
....................................................................................................................9
4.3控制模式:
....................................................................................................................9
5、集水井监控..............................................................................................................................10
6、变配电系统基本监控...............................................................................................................11
6.1高压测监视..................................................................................................................11
6.2低压测监视..................................................................................................................11
6.3变压器监视..................................................................................................................11
6.4直流操作电源监视......................................................................................................12
7、给排水系统监控......................................................................................................................13
7.1监控功能:
..................................................................................................................13
7.2控制方案:
..................................................................................................................14
8、电梯系统..................................................................................................................................15
8.1监控内容......................................................................................................................15
9、其他设备监控原理...................................................................................................................16
9.1锅炉设备......................................................................................................................16
9.2热交换器监控..............................................................................................................16
1、空调机组监控
1.1监控内容
新风温度、湿度测量
过滤器堵塞报警监测
送/回风温度、湿度测量
空气质量检测
防冻开关状态监测
分机压差报警监测
送/回风机运行状态监测、故障监测、手自动状态监测、启停控制加湿器阀门开关控制
新风口风门开度控制
回风/排风风门开度控制
冷/热水阀门开度调节
1.2控制方案
(1)温度调节:
定风量空调的节能是以回风温度为被调参数,DDC控制器计算回风温度与给定值比较差生的偏差,按照预定的调节规律(一般为PID)输出调节信号控制冷/热水阀的开度以控制冷/热水量,使气温保持在设定值。
(2)湿度调节:
回风湿度调节与回风温度调节过程基本相同,把回风湿度值与给定的值比较,产生偏差,DDC控制器按PI规律调节加湿器电动阀开度,将房间相对湿度控制在设定值。
(3)风门调节:
根据新风的温湿度、回风的温湿度在DDC进行回风及新风焓值计算,按回风和新风的焓值比例及空气质量检测值对新风的需求量,控制新风筏和回风阀的开度比例,使系统在最佳新风/回风状态下运行。
(4)过滤器压差报警、机组防冻保护:
用压差开关测量过滤器的两端压差,当压差超限时报警,表明过滤网两侧灰尘堆积严重,需要清理清洗。
防霜冻开关监测表冷器的出风侧温度,当温度低于5℃时报警,表明室外温度过低,应关闭风门,同时关闭风机,不使换热器温度进一步降低。
(5)空气质量控制:
为保证空调区域的空气质量,应选用空气质量传感器,当房间的CO2、CO浓度升高时,传感器输出信号到DDC控制器,控制器输出控制信号,控制新风风门的开度以增加新风量。
(6)定时运行与远程控制:
控制系统能够依据预定的运行时间表,实现空调机组的按时启停。
1.3启动顺序
定风量空调启动顺序控制:
新风风门、回风风门、排风口风门开启-----送风机启动-----回风机启动-----冷热水调节阀开启-----加湿阀开启。
定风量空调停止顺序控制:
关加湿阀-----关冷热水阀-----送风机停机-----新风风门、回风风门、排风口风门关闭。
2、新风系统监控
2.1监控内容
监测送风温湿度
由风压差开关测量风机两侧压差,监视风机运行状态,异常即报警,并
记录风机累计运行时间
监测风机故障报警
由风压差开关测量空气过滤器两侧压差,压差超过设定