NEC微波调测指导书.docx
- 文档编号:27624926
- 上传时间:2023-07-03
- 格式:DOCX
- 页数:59
- 大小:7.47MB
NEC微波调测指导书.docx
《NEC微波调测指导书.docx》由会员分享,可在线阅读,更多相关《NEC微波调测指导书.docx(59页珍藏版)》请在冰豆网上搜索。
NEC微波调测指导书
微波调测指导书
1调测准备...........................................................................................................1
2调试工具...........................................................................................................1
3PASOLinkNEOSTM-1设备调试步骤..........................................................1
3.1系统登陆......................................................................................................................1
3.1.1登陆PNMTj软件.........................................................................................2
3.1.2PNMTj系统界面..........................................................................................2
3.2参数设置.....................................................................................................................3
3.2.1站点名设置....................................................................................................4
3.2.2PASOLinkSTM-1设备初始参数设置........................................................5
3.2.3调制方式设置................................................................................................7
3.2.4传输容量设置................................................................................................7
3.2.5频率设置........................................................................................................7
3.2.6初始参数设置完成........................................................................................7
3.3调试设置.....................................................................................................................8
3.3.1维护菜单打开设置........................................................................................8
3.3.2天线模式设置................................................................................................9
3.3.3监控接收电平“RXLevel”.......................................................................10
3.4衰减值设置................................................................................................................11
3.4.1发送功率设置...............................................................................................12
3.4.2门限电平值设置...........................................................................................12
3.4.3维护菜单关闭设置.......................................................................................13
3.5查看ODU设备的各种参数.....................................................................................15
3.5.1进入ODU参数界面....................................................................................15
4PASOLinkNEO设备调试步骤.....................................................................17
4.1系统登陆....................................................................................................................17
4.2参数设置....................................................................................................................17
4.2.1PASOLinkNEO设备初始参数设置...........................................................18
4.2.2调制方式设置...............................................................................................20
4.2.3传输容量设置...............................................................................................21
5PASOLink(NEO、NEOSTM-1)设备IP设置..............................................22
5.1PASOLinkNEO设备IP设置................................................................................22
6PASO(NEO、STM-1)信道设置.................................................................25
6.1查看告警信道.............................................................................................................25
6.2不用信道屏蔽设置....................................................................................................26
7PSASOLink(1+1、1+0)设备调试步骤.....................................................28
7.1系统登陆.....................................................................................................................28
7.1.1登陆PNMTj软件........................................................................................29
7.1.2进入PNMT系统界面..................................................................................29
7.2参数设置.....................................................................................................................30
7.2.1频率设置.......................................................................................................30
7.2.2站点名设置...................................................................................................32
7.2.3监控接收电平值“RXLevel”...................................................................33
7.3衰减值设置.................................................................................................................33
7.3.1衰减值输入方法...........................................................................................33
7.3.2门限电平值设置...........................................................................................34
7.4PASOLink(1+1、1+0)设备IP设置..................................................................34
7.4.1IP系统配置设置..........................................................................................34
7.4.2IP网络配置设置..........................................................................................34
7.5PASOLink(1+1、1+0)信道设置..........................................................................39
7.5.1查看告警信道...............................................................................................39
7.5.2不用信道屏蔽设置.......................................................................................40
8微波常见故障与处理......................................................................................41
8.1一般原则..................................................................................................................41
8.2常见故障与处理......................................................................................................41
NEC微波调测指导书
一、调测准备
首先在笔记本电脑上安装NEC两种测试软件:
1、PNMTj软件,用于PASOLinkNEO、PASOLinkNEOSTM-1设备测试,同时可兼容PASOLINK(1+0;1+1)设备测试。
2、PNMT软件,用于PASOLINK(1+0;1+1)设备测试。
再次拿到调测微波的链路规划信息和各站点的微波参数设计值,一般由微波设计人员提供。
,
二、调测工具
笔记本电脑、测试数据线(LCT线、PNMT线)、数字万用表、误码仪。
三、PASOLinkNEOSTM-1设备调试步骤
3.1系统登陆
图1
3.1.1登陆PNMTj软件
在电脑开始程序中找到PNMTj调试软件,点击Pnmt。
图2
3.1.2PNMTj系统界面
点击“Pnmt”以后系统将自动生成“PNMTj”软件登录界面,在“Username”:
输入用户名“admin”,然后点击回车键“Enter”。
系统自动联接微波设备IDU,如图3所示。
图3
图4
“PNMTj”软件登陆IDU成功,生成系统界面,显示各种参数。
在图4中我们可以看到一跳微波的参数,左边是本端,站点名:
10016;右边是对端,站点名是10018;在“PNMTj”软件中我们可以在本端登陆,进行初始参数设置,同时也可以在本端进行对端参数的设置和修改。
例如站点名的输入,频率的输入方法,衰减值的输入方法,等等……下面将一一介绍。
3.2参数设置
图5
3.2.1站点名设置
进入参数设置系统以后,在系统界面中点击配置“Configuration”,再选者设备设置“EquipmentSetup”,系统将会弹出Setup窗口,如图6右边所示。
图6
在“Setup”窗口中找到“NEName”,双击“NEName”以后将会弹出站点名输入窗口。
在“NENAME”窗口中输入规划设计中的ID号和站点名,例如输入“10016NefasSILK”,输入完成以后,点击执行“Execute”系统将会自动默认,然后再点击关闭“Close”,站点名字输入完成。
图7
图8
3.2.2PASOLinkNEOSTM-1设备初始参数设置
点击Setup,弹出PASOSTM—1设备窗口,在此窗口中,我们能看到PASOSTM-1设备的各项初始配置参数,图8和图9中如何来设置这些初始配置参数,将在下面介绍。
图9
图10
点击图8中设置“Setup”以后,再点击图9中配置“Configure”进入用户设置界面“Userinterface”,在“Userinterface”右边选项栏中我们要选者于设备型号一样的型号配置,在图10中我们可以看到里面有4个选项,我们要选者的是与设备相匹配的初始配置“SDHSTM-1”,选者以后系统将会自动默认,下一步设置“Redundancysetting”。
图11
“Redundancysetting”选项栏中我们将选“1+1(HotStandbyTERM)”,选者以后系统将自动默认,其他的选项中是系统的默认值,不用在设置,最后点击下一步“next”。
图12
3.2.3调制方式设置
在调制方式中“ModulationScheme”会有多种调制方式,128QAM、64QAM、32QAM
等;现在所看到图12中PASOSTM-1设备选者128QAM。
3.2.4传输容量设置
传输容量“TransmissionCapacity”有158MB、100MB等,PASOSTM-1设备选者
158MB。
3.2.5频率设置
在图12中找到发送频率“TXRFFrequency”,例如输入发送频率:
19005.000;系统自
动默认。
点击下一步“Next”。
3.2.6初始参数设置完成
最后点击完成“Finish”,完成所有初始参数设置。
图13
3.3调试设置
回到系统生成界面中,在系统界面中点击配置“Configuration”,再选者维护菜单“Maintenance”,系统将会弹出维护窗口,如图15右边所示
图14
图15
3.3.1维护菜单打开设置
在维护菜单中要进行菜单第一项“Maintenance”和最后两项“AntennaAlignmentMode”设置。
点击维护“Maintenance”,将会弹出“MAINT”窗口,再选者打开“On”,点击执行“Execute”,“Maintenance”栏右边选项将变成黄颜色,然后关掉窗口,这样维护菜单就打开了。
图16
图17
3.3.2天线模式设置
打开天线模式“AntennaAlignmentMode”的方法和打开维护“Maintenance”方法一样,这样整个维护菜单就全部设置完成。
设置完成以后,开始查看接收电平值。
图18
3.3.3监控接收电平“RXLevel”
回到系统界面中点击监控“PerformanceMonitor”,再选者测试“Metering”,系统将会弹出“Metering”窗口,如图19所示。
图19
PASOSTM-1是1+1备份的,所以在图19中会看到两项发送功率“No.1TXPower”、“No.2TXPower”和两项接收电平“No.1RXLevel”、“No.2RXLevel”,实际在监控的时候,系统是运行单发双收,所以在图19中只能看到“No.2TXPower”有发送功率,而“No.1TXPower”没有发送功率;开始监控时,同时通知塔上的安装工人开始调试微波,在调试过程中,就可以监控到接收电平值“No.1RXLevel”、“No.2RXLevel”的变化,当接收电平值达到设计值时,通知安装工个人锁定微波。
图20中红色栏是设计值。
图20
3.4衰减值设置
调试完以后,设置发送功率的衰减值,在调试过程中是不能设置衰减值的,所以在调试完成以后再增加发送功率衰减值的设置,在系统界面中点击配置“Configuration”,再选者“Provisioning”菜单,系统弹出“Provisioning”窗口,如图22右边所示。
图21
图22
3.4.1发送功率设置
在菜单中要设置的是手动控制发送功率“MTPCTXPower”和自动控制传送功率门限电平值“ATPCthresholdLevel”两项参数。
找到手动控制传送功率“MTPCTXPower”选项,点击“MTPCTXPower”系统弹出TXPower窗口,找到第一项“MTPCTXPower”,根据微波设计值输入相应的衰减值,例如:
根据图20红色一栏,找到衰减“MTPCLoss”相应的衰减值,输入-6dBm的衰减值,点击执行“Execute”系统就自动默认,点击关闭“Close”,衰减值输入完成,如图23所示。
图23
3.4.2门限电平值设置
自动控制传送功率门限电平值“ATPCthresholdLevel”一般设置为“-60dBm”,设置方法同“MTPCTXPower”。
图24
3.4.3维护菜单关闭设置
关闭维护菜单“MAINT”。
进入维护菜单有两种方法:
①、从系统界面中点击配置“Configuration”,单击维护菜单“Maintenance”,如图14所示。
②、从系统界面中单击维护菜单“MAINT”进入,图24所示。
图25
在维护菜单中要进行菜单第一项“Maintenance”和最后两项“AntennaAlignmentMode”设置。
首先关闭天线模式“AntennaAlignmentMode”,操作如图25,点击天线模式“No.1AntennaAlignmentMode”将会弹出操作窗口,再选者关闭“Off”,点击执行“Execute”,“No.1AntennaAlignmentMode”栏将变成白色,然后关闭窗口,如图26所示。
图26
图27
再关闭“No.2AntennaAlignmentMode”,最后关闭“Maintenance”操作方法同上,这样维护菜单就关闭了,如图27所示,最后关闭窗口。
系统将返回系统界面。
如图28所示。
所有调试工作完成。
同时可以在本端站完成对端站10018的参数配置,操作方法完全一样。
3.5查看ODU设备参数
图28
3.5.1进入ODU参数界面
在系统界面中,单击目录“Inventory”菜单,弹出目录窗口,从图29、图30、图31可以看到全部的ODU的信息,包括,出厂编号,OUD高低端,子带等信息。
供大家参考。
图29
图30
图31
四、PASOLinkNEO设备调试步骤
“PASOLinkNEO”设备和“PASOLinkNEOSTM-1”设备测试是用同一个软件PNMTj,所以在系统登陆,参数设置,调试设置和衰减值设置操作方法是完全一样的,只是在参数设置中选者的设备初始参数配置不同,下面简单介绍一下。
4.1系统登陆
电脑开始→程序→PNMTj→Pnmt→输入用户名admin→点击回车键“Enter”进入系统界面如图32详细操作方法请参考3.1系统登陆。
图32
4.2参数设置
“PASOLinkNEO”设备和“PASOLinkNEOSTM-1”设备所有设置操作方法相同,在设备初始参数配置方面介绍一下不同之处。
图33
4.2.1
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NEC 微波 指导书