IVD产品CE认证大体要求检查表
AnnexI
EssentialRequirements
accordingtoDirective98/79/EC,oninvitrodiagnosticmedicaldevices
Device:
Trademark:
Manufacturer:
Distributor:
Accessories:
Draftedby:
Date:
Reviewedby:
Date:
Approvedby:
Date:
A.
GENERALREQUIREMENTS
1.
Thedevicemustbedesignedandmanufacturedinsuchawaythat,whenusedundertheconditionsandforthepurposesintended,theywillnotcompromise,directlyorindirectly,theclinicalconditionorthesafetyofpatients,orthesafetyandhealthofusersor,whereapplicable,otherpersons,orthesafetyofproperty.Anyriskswhichmaybeassociatedwiththeirusemustbeacceptablewhenweighedagainstthebenefitstothepatientandbecompatiblewithahighlevelofprotectionofhealthandsafety.
2.
Thesolutionsadoptedbythemanufacturerforthedesignandconstructionofthedevicesmustconformtosafetyprinciples,takingaccountofthegenerallyacknowledgedstateoftheart..
Inselectingthemostappropriatesolutions,themanufacturermustapplythefollowingprinciplesinthefollowingorder:
-eliminateorreducerisksasfaraspossible(inherentlysafedesignandconstruction)-whereappropriatetakeadequateprotectionmeasuresincludingalarmsifnecessary,inrelationtorisksthatcannotbeeliminated.-informusersoftheresidualrisksduetoshortcomingsoftheprotectionmeasuresadopted.
3.
ThedevicesmustbedesignedandmanufacturedinsuchawaythattheyaresuitableforthepurposesreferredtoinArticle1
(2)(b),asspecifiedbythemanufacturer,takingaccountofthegenerallyacknowledgedstateoftheart.Theymustachievetheperformances,inparticular,whereappropriate,intermsofanalyticalsensitivity,diagnosticsensitivity,analyticalspecificity,diagnosticspecificity,accuracy,repeatability,reproducibility,includingcontrolofknownrelevantinterference,andlimitsofdetection,statedbythemanufacturer.
Thetraceabilityofvaluesassignedtocalibratorsand/orcontrolmaterialsmustbeassuredthroughavailablereferencemeasurementproceduresand/oravailablereferencematerialsofahigherorder.
4.
Thecharacteristicsandperformancereferredtoinsections1and3mustnotbeadverselyaffectedtosuchadegreethatthehealthorthesafetyofthepatientsortheuserand,whereapplicable,ofotherpersonsarecompromisedduringthelifetimeofthedeviceasindicatedbythemanufacturer,whenthedeviceissubjectedtothestresseswhichcanoccurduringnormalconditionsofuse.Whennolifetimeisstated,thesameappliesforthelifetimereasonablytobeexpectedofadeviceofthatkind,havingregardtotheintendedpurposeandtheanticipateduseofthedevice.
5.
Thedevicesmustbedesigned,manufacturedandpackedinsuchawaythattheircharacteristicsandperformancesduringtheirintendedusewillnotbeadverselyaffectedduringtransportandstorage(temperature,humidity,etc.)takingintoaccounttheinstructionsandinformationprovidedbythemanufacturer.
B.
DESIGNANDMANUFACTURINGREQUIREMENTS
1.
ChemicalandPhysical
ThedevicesmustbedesignedandmanufacturedinsuchawayastoachievethecharacteristicsandperformancesreferredtoinSectionAonthe"GeneralRequirements".Particularattentionmustbepaidtothepossibilityofimpairmentofanalyticalperformanceduetoincompatibilitybetweenthematerialsandthespecimens(suchasbiologicaltissues,cells,bodyfluidsandmicro-organisms)intendedtobeusedwiththedevice,takingaccountofitsintendedpurpose.
Thedevicesmustbedesigned,manufacturedandpackedinsuchawayastoreduceasfaraspossibletheriskposedbyproductleakage,contaminantsandresiduestothepersonsinvolvedinthetransport,storageanduseofthedevices,takingaccountoftheintendedpurposeoftheproduct.
2.
Infectionandmicrobialcontamination
Thedevicesandtheirmanufacturingprocessesmustbedesignedinsuchawayastoeliminateorreduceasfaraspossibletheriskofinfectiontotheuserorotherpersons.Thedesignmustalloweasyhandlingand,wherenecessary,reduceasfaraspossiblecontaminationof,andleakagefrom,thedeviceduringuseand,inthecaseofspecimenreceptacles,theriskofcontaminationofthespecimen.Themanufacturingprocessesmustbeappropriateforthesepurposes.
Whereadeviceincorporatesbiologicalsubstances,therisksofinfectionmustbereducedasfaraspossiblebyselectingappropriatedonorsandappropriatesubstancesandbyusingappropriatevalidatedinactivation,conservation,testandcontrolprocedures.
Deviceslabelledeitheras‘STERILE’orashavingaspecialmicrobiologicalstatemustbedesigned,manufacturedandpackedinanappropriatepack,accordingtoproceduressuitableforensuringthattheyremainintheappropriatemicrobiologicalstateindicatedonthelabelwhenplacedonthemarket,underthestorageandtransportconditionsspecifiedbythemanufacturer,untiltheprotectivepackagingisdamagedoropened.
Deviceslabelledeitheras‘STERILE’orashavingaspecialmicrobiologicalstatemusthavebeenprocessedbyanappropriate,validatedmethod.
Packagingsystemsfordevicesotherthanthosereferredtoinsectionmustkeeptheproductwithoutdeteriorationatthelevelofcleanlinessindicatedbythemanufacturerand,ifthedevicesaretobesterilisedpriortouse,reduceasfaraspossibletheriskofmicrobialcontamination.
Stepsmustbetakentoreduceasfaraspossiblemicrobialcontaminationduringselectionandhandlingofrawmaterials,manufacture,storageanddistributionwheretheperformanceofthedevicecanbeadverselyaffectedbysuchcontamination.
Devicesintendedtobesterilized,mustbemanufacturedinappropriatelycontrolled.environmental)conditions.
Packagingsystemsfornon-steriledevicesmustkeeptheproductwithoutdeteriorationinthelevelofcleanlinessstipulatedand,ifthedevicesaretobesterilizedpriortouse,minimizetheriskofmicrobialcontamination;thepackagingsystemmustbesuitabletakingaccountofthemethodofsterilizationindicatedbythemanufacturer.
3
Manufacturingandenvironmentalproperties
Ifthedeviceisintendedforuseincombinationwithotherdevicesorequipment,thewholecombination,includingtheconnectionsystemmustbesafeandmustnotimpairthespecifiedperformancesofthedevices.Anyrestrictionsontheusemustbeindicatedonthelabelorintheinstructionsforuse.
Devicesmustbedesignedandmanufacturedinsuchawayastoreduceasfaraspossibletheriskslinkedtotheiruseinconjunctionwithmaterials,substancesandgaseswithwhichtheymaycomeintocontactduringnormalconditionsofuse
Devicesmustbedesignedandmanufacturedinsuchawayastoremoveorreduceasfaraspossible:
-theriskofinjurylinkedtotheirphysicalfeatures(inparticularaspectsofvolumexpressure,dimensionand,whereappropriate,ergonomicfeatures),-riskslinkedtoreasonablyforeseeableexternalinfluences,suchasmagneticfields,externalelectricaleffects,electrostaticdischarge,pressure,humidity,temperatureorvariationsinpressureoraccelerationoraccidentalpenetrationofsubstancesintothedevice.
Devicesmustbedesignedandmanufacturedinsuchawayastoprovideanadequatelevelofintrinsicimmunityofelectromagneticdisturbancetoenablethemtooperateasintended.
Devicesmustbedesignedandmanufacturedinsuchawayastoreduceasfaraspossibletherisksoffireorexplosionduringnormaluseandinsinglefaultcondition.Particularattentionmustbepaidtodeviceswhoseintendeduseincludesexposuretooruseinassociationwithflammablesubstancesorsubstanceswhichcouldcausecombustion.
Devicesmustbedesignedandmanufacturedinsuchawayastofacilitatethemanagementofsafewastedisposal.
Themeasuring,monitoringordisplayscale(includingcolourchangeandothervisualindicators)mustbedesignedandmanufacturedinlinewithergonomicprinciples,takingaccountoftheintendedpurposeofthedevice.
4
Deviceswhichareinstrumentsorapparatuswithmeasuringfunction
Deviceswhichareinstrumentsorapparatushavingaprimaryanalyticalmeasuringfunctionmustbedesignedandmanufacturedinsuchawayastoprovideadequatestabilityandaccuracyofmeasurementwithinappropriateaccuracylimits,takingintoaccounttheintendedpurposeofthedeviceandofavailableandappropriatereferencemeasurementproceduresandmaterials.Theaccuracylimitshavetobespecifiedbythemanufacturer.
Whenvaluesareexpressednumerically,theymustbegiveninlegalunitsconformingtotheprovisionsofCouncilDirective80/181/EECof20December1979ontheapproximationofthelawsoftheMemberStatesrelatingtounitsofmeasurement.
5
Protectionagainstradiation
Devicesshallbedesigned,manufacturedandpackagedinsuchawaythatexposureofusersandotherpersonstotheemittedradiationisminimised.
Whendevicesareintendedtoemitpotentiallyhazardous,visibleand/orinvisibleradiation,theymustasfaraspossiblebe:
?
designedandmanufacturedinsuchawayastoensurethatthecharacteristicsandthequantityofradiationemittedcanbecontrolledand/oradjusted,?
fittedwithvisualdisplaysand/oraudiblewarningsofsuchemissions.
Theoperatinginstructionsfordevicesemittingradiationmustgivedetailedinformationastothenatureoftheemittedradiation,meansofprotectingtheuser,andonwaysofavoid