外文翻译浅谈高层建筑供配电系统设计
中文4323字
外文资料翻译
Powersupplysystemofhigh-risebuildingdesign
Abstract:
withthecontinuousdevelopmentofcitysize,moreandmorehigh-risebuildings,thereforehigh-risebuildingelectricaldesigntothedesignershadtoface.Inthispaper,anengineeringexample,describestheelectricaldesignofhigh-risebuildingsandsomeofthemoretypicalissuesofuniversalsignificance,combinedwiththeactualpracticeofanengineeringsolutiontotheproblemdescribed.
Keywords:
high-risebuilding;electricaldesign;distribution;loadcalculation
1ProjectOverview
Thecommercialcomplexproject,withatotalconstructionareaof405570m2,onthegroundfloorareaof272330m2,undergroundconstructionareaof133240m2,themainheightof99m.Projectcomponentsare:
twoofficebuildings,constructionareais70800m2,28layers,thestandardstoryis3.2m.
2LoadCalculation
1)Loadcharacteristics:
electricload,muchlargerthanthe"nationalcivilengineeringtechnicalmeasures"Large120W/m2indicators,especiallyintheelectricityloadmorefood,anddifferenttypesoffoodandbeveragecateringdifferentculturalbackgroundsalsohigh.
2)theuncertaintyofalargeload,becausethecommercialrealestaterentsareoftenbasedonmarketdemand,andconstantlyadjustthenatureoftheshops,makingtheloadinthedynamicchanges.
3)Thereisnospecificationandtechnicalmeasuresinthedifferenttypesofcommercialprojectsrefertothedetailedparametersoftheshops,engineeringdesignloadcalculationinthelackofdata,inmostcasestorelyonstaffwithpreviousexperienceinengineeringdesigncalculations.
Loadtheselectionofparameters:
fortheaboveproblems,theloadcalculation,thefirstdeveloperofsalesandgoodcommunication,todeterminetheformoflayersoftheformsandnatureoffloorarea,whichiscalculatedonthebasisofelectricalloadbasis;followedtodetermineparameterindexwithintheunitareaofshopsisalsoveryimportantandcomplexbecausethereisnoclearindicatorofthespecificationcanreferto;anddifferentlevelsofeconomicdevelopmentbetweencitiesisnotbalanced,powerindicesarealsodifferent;willbeinthesamecity,differentregionshavedifferentconsumergroups.
3)theneedtofactorinthechoice:
parametersdetermined,theneedforloadcalculation.Needtofactorcommonlyusedmethod,thecalculationwillnotrepeatthem.Needtoexploreistheneedforcoefficientselection,whichinthecurrentspecifications,manualsandthe"unifiedtechnicalmeasures"isalsonotclearrequirements,basedonyearsofdesignexperiencethatmostendshopsinthedistributionorlevelwithinthehouseholddistributionboxwithcaseKxgenerallytakeawhile,inthecalculationofthelooproutetotake0.7to0.8,thedistributiontransformersinthesubstationcalculationstake0.4to0.6.
3substationsset
Loadcalculationbasedontheresultsofthisprojectthetotalinstalledcapacityoftransformer43400Kv.A,afterrepeatedconsultationswiththepowercompany,respectively,intheprojectinnorthern,centralandsouthernthreesectionssetthethreebuildingsintothreepowersubstations,1#set6sets2500Kv.Atransformersubstation,takethenorthernsectionofpowersupply;2#41600Kv.Atransformersubstationslocated,plus6sets2000Kv.Atransformers,takethemiddleofthepowersupply,inadditionto5Taiwan10Kv.Ahigh-pressurewaterchillers(total4000Kv.A);3#substationlocated2unitsplus2units1000Kv.A2000Kv.Atransformers,takethesouthernsectionofA,Btwoofficesupply.10Kvpowerconfigurationofthisprojectintotwopoints,eachatthetwo10Kvlines,thepowercompanyundertheprovisionsof10Kvpowercapacity:
maximumloadperchannelisaboutto11000Kv.A,twoisthe22000Kv.A,design#1,3#combinationofasubstation10Kv,powerline,withatotalcapacityof21000Kv.A;2#substationtransformersand10Kv,10Kvchillerssharingapowerline,withatotalcapacityof22400Kv.A.Thedesignofthesubstationlayout,inadditiontomeetingregulatoryrequirements,italsoneedtoconsiderthehigh-pressurecabinets,transformersandlowvoltagepowersupplycabinetbyorderofarrangement,especiallyinlowvoltagedistributioncabinettofeedthecablesmoothandeasyinspectiondutyproblemsarenotseriouslyconsidertheconstructionofthecablecrossingwillcausemorelongdetour,awasteoffloorspace,andconvenientinspectionsandotherissues【8】.
4smallfireloadpowersupply
Inthedesignoflargecommercialprojectsoftenencountersmallfireloadofelectricalequipmentandmoredisperseddistribution,iffedbyasubstation,asubstationwillbefedalotoflow-voltagelow-currentcountercircuitbreakingcapacitycircuitbreakerandconductorofthedynamicandthermalstabilityinacertainextent.AccordingtoGB50045-1995"fireprotectiondesignoftallbuildings,"rule"shouldbeusedinFireEquipmentdedicatedpowersupplycircuit,thepowerdistributionequipmentshallbeprovidedwithclearsigns."Interpretationoftheprovisionsofthepowersupplycircuitmeans"fromthelow-voltagemaindistributionroom(includingthedistributionofelectricalroom)tolastadistributionbox,andthegeneraldistributionlinesshouldbestrictlyseparated."Inthisdesign,theuseofmethodstoincreasethelevelofdistribution,thatisdifferentfromthesubstationbussegments,respectively,afirefedaspecialcircuit,setinplacetwodistributioncabinets,distributioncabinetsandthentheresultingradialallocatedtotheendofthedualpowertovoteeachbox,sothatnotonlymeetsthespecificationrequirementsfordedicatedpowersupplycircuit,butalsotoavoidfeedingthesubstationlevelofmanysmallcurrentloop.
5,thechoiceofcircuitbreakerandconductor
Commercialrealestateprojectsusetheroomastheuncertaintyinthechoiceofcircuitbreakersandconductorsmustbeconsideredinacertainmargintomeettheneedscausedbyadjustmentoftheloadchanges.Accordingtothischaracteristic,increaseduseinthedesignoftheplugbus-powered,notonlymeettherequirementsoflargecarryingcapacity,andalsoallowstheflexibilitytoincreasesupplyanddistribution,arereservedineachshaftintheplug-boxbackupinordertochange,accordingtochangesinupperandlowerload,toadjust.Forexample:
abusisresponsibleforashaft1to3layersofpower,whenalayerduetothechangeincapacityincreases,whilethe3-layercapacityisreduced,youcanuseaspareplugboxlayeroffthe3-layer1layercapacityrationing.Thisleveldistributioninthesubstation,selectthecircuitbreakertochoosethesettingvaluewhenthecircuitbreakertoadjusttochangesattheendtoadjusttheloadsettingvalue;inthebusandthetransformercircuitbreakeraccordingtothechoiceofthegeneralframeworkofvaluestoselect.Forexample:
Routecertainequipmentcapacity530Kv,Kxtake0.7tocalculatecurrentof704A,selecttheframecircuitbreakeris1000A,tuningis800A;currenttransformerforthe1000/50;buscarryingcapacityforthe1000A,thisroadcanmeetthemaximum1000Acurrentloadrequirements,evenifthereisadjustment,powerdistributionswitchesandcircuitcannotmakebigchanges.
6layerdistributionboxset
Accordingtothedivisionoflayersoffireprotectiondistrict,respectivelynumberedasA~Klayerswithinthesetlevelshaftfortheretaillightingpowerdistributionbox,withoneononepowersupplyshopsinradialpower.Shouldbenotedthattheformsofthecomplexlayersoflayersoffirepartition,doesnotcorrespondtothelower,makingsomeofshaftpowerinchargeofthefiredistrictatthesametime,alsoresponsibleforthepowersupplyadjacenttothefiredistrict.Atdesigntime,usingtheprincipleofproximity,whilealsotakingintoaccounttheburdenofthewholetrunkloadconditions,sothateachshaftasfaraspossibleamorebalancedload.Prerequisites
Theloopthatyouwanttoauto-tunemustbeinautomaticmode.TheloopoutputmustbecontrolledbytheexecutionofthePIDinstruction.Auto-tunewillfailiftheloopisinmanualmode.
Beforeinitiatinganauto-tuneoperationyourprocessmustbebroughttoastablestatewhichmeansthatthePVhasreachedsetpoint(orforaPtypeloop,aconstantdifferencebetweenPVandsetpoint)andtheoutputisnotchangingerratically.
Ideally,theloopoutputvalueneedstobenearthecenterofthecontrolrangewhenauto-tuningisstarted.Theauto-tuneproceduresetsupanoscillationintheprocessbymakingsmallstepchangesintheloopoutput.Iftheloopoutputisclosetoeitherextremeofitscontrolrange,thestepchangesintroducedintheauto-tuneproceduremaycausetheoutputvaluetoattempttoexceedtheminimumorthemaximumrangelimit.
Ifthisweretohappen,itmayresultinthegenerationofanauto-tuneerrorcondition,anditwillcertainlyresultinthedeterminationoflessthannearoptimalsuggestedvalues.
Auto-HysteresisandAuto-Deviation
Thehysteresisparameterspecifiestheexcursion(plusorminus)fromsetpointthatthePV(processvariable)isallowedtomakewithoutcausingtherelaycontrollertochangetheoutput.ThisvalueisusedtominimizetheeffectofnoiseinthePVsignaltomoreaccuratelydeterminethenaturaloscillationfrequencyoftheprocess.
Ifyouselecttoautomaticallydeterminethehysteresisvalue,thePIDAuto-Tunerwillenterahysteresisdeterminationsequence.Thissequenceinvolvessamplingtheprocessvariableforaperiodoftimeandthenperformingastandarddeviationcalculationonthesampleresults.
Inordertohaveastatisticallymeaningfulsample,asetofatleast100sample
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 外文 翻译 浅谈 高层建筑 配电 系统 设计