ITA70安装与配置
InManagementNode
1.InstallSNMPprotocolform“add/removeprogram”.
2.InstallServerAdministrator.
3.Goto“controlplane/administrativetools/services”.SelectSNMPanddoubleclick.
ConfigureSNMPcommunity/trapasfollowing.Andthenrestarttheservice.
InManagementStation
1.InstallSNMPprotocolfrom“add/removeprogram”.
2.InstallDELLSystemManagementStation.MustselectITAduringinstallation.
3.LoginITAwithyourdomainadministratoraccount
4.ConfigureITASMTPproperty.
5.Addnewsearchrange.
Step1,addhostnameorIPaddressformanagementnodeandclicknext.Ifyouhavemultiplesystem,youcanenteraIPrange.
Step2,usedefaultfortimeoutsettingandclicknext.
Setp3,configureSNMPcommunityname,itshouldbethesameasyourmanagementnode.
Step4,usedefaultsettingforCIMsearchingandclicknext.
Step5,usedefaultsettingandclicknext.
Step6,clickfinish
6.Thenewrangewillappearinthe“searchrange”.Thenriggerasearchforthenewrange.
7.Monitorthesearchprocessandwaititcomplete.IfpreviousconfigurationisOK,youwillfindnewsystemondevicemenu.
8.Clicktoselectthesystem;youcancheckthe“SystemSummary/Alarm/ESMLog”.
ManagementTask
EmailAlarm
1.GotoAlarmmenu,configurenewalarmaction.
2.ConfigurenewactionasMailAlarm.
Step1,selecttheactiontype.
Step2,entermailboxandtestthesetting.
Step3,configureeventfilter.
Step4,selectthefilterandclicknext.
Step5,clickfinishandITAisreadytomonitoryoursystem.
Ifthesystemhasalarm,youwillreceiveaalarmmail.
WakeonLAN/Shutdownsystem
1.Selectmanagementtask.
2.Configurenewtask.
3.Selectsystemsyouwanttoapplytothistask.
4.Configurethetaskschedule.
5.Specifytheusertoperformtask
6.Clickfinish,thetaskwillbeissuedtotargetsystem.