诺西认证考试题库汇总题目.docx
- 文档编号:24705826
- 上传时间:2023-05-31
- 格式:DOCX
- 页数:37
- 大小:934.36KB
诺西认证考试题库汇总题目.docx
《诺西认证考试题库汇总题目.docx》由会员分享,可在线阅读,更多相关《诺西认证考试题库汇总题目.docx(37页珍藏版)》请在冰豆网上搜索。
诺西认证考试题库汇总题目
whatwholecommandisusefulwhenconversiondatabasefromDBAformattoASCformatunderBr6.0
Adbaemcreatecmd–
dbfile.dba-dbinput
Bdbaemcreatecmd
dbfile.dbadbinput
Cdbaemcreatecmd-dbinput
DdbaemcreatecmddbintputD
NO5.1
Whatfilenameiscanbe
workingunderDBAEM(Br60
whenDBAconversionASC.
Adb26415.dba.
Bdb25416.dba
Cdbfile.asc
Ddbfile.dba
DNO5.1
Whatfilenameiscanbe
workingunderDBAEM(Br80
whenASCconversionDBA.
Acmd27134.asc
Bcmd28134.asc
Ccmd27117.asc
Dcmd28117.asc
DNO5.1
What’skindfileswillautomaticgeneratedinyourDBAEMdirectorywhenwemadeconversioncommandfromASCformattoDBAformatwas
completed
Asnx*****.asc
Bdef*****.asc
Cdpm*****.ovl
Drsp*****.ascD
NO5.1
whatisDBAEMfunction
useful?
Amodifyparameter
Bbuildnewdatabase
Cdatabaseoptimize
Ddatabaseconversion
DNO5.1
Whatcommandispreferred
whenupgradedatabasefrom
Br70toBr80
Aconverfile-27***-28***
Bconverfile27***.asc
28***.asc
Cconverfile-27***.asc–
28***.asc
Dconverfile27***28***
DNO5.1
WhatcommandispreferredwhenupgradedatabasefromBr60toBr70
Aconverfile-26***-27***
Bconverfile26***.asc27***.asc
Cconverfile-26***.asc–27***.asc
Dconverfile26***27***D
NO5.1
What’skindfileswillautomatic
generatedatonceinyour
DBAEMdirectorywhenwe
madeconversioncommand
fromASCformattoDBAformat
wasstarting
Areadme.txt
Bdefine.txt
Cdpm_.ovl
Dbscinfo.txt
DNO5.1
HereIgotonemessage“
ERROR>bsc15.ascline1128
-SYNTAXERROR”please
givethereasonpossibleabout
thisalarm.
Atheparametersetwrong
value
Btheobjectsetwrongname
Cthevaluesetoutofrange
Dthesignsetwrongsymbol
DNO5.1
HereIgotonemessage“UNKNOWNATTRIBUTE”pleasegivethereasonpossibleaboutthisalarm.
Atheparametersetwrongvalue
Btheobjectsetwrongname
Cthevaluesetoutofrange
DthesignsetwrongsymbolB
NO5.1
HereIgotonemessage“
CREATELPDLM
NAME=BTSM:
18/LPDLM:
0:
RESP="UNSUCCESSFUL_NO
_MORE_LAPDPOOL_AVAILA
BLE"trytogivethereason
possibleaboutthisalarm.
Aparametererror
Bsymbolerror
Cnamingerror
Dvalueoutofrange
DNO5.1
HereIgotonemessage“CREATEFHSY
NAME=BTSM:
12/BTS:
0/FHSY:
1:
RESP="UNSUCCESSFUL_TRX_FREQ_NOT_FOUND”trytogivethereasonpossibleabout
thisalarm.
Acreatebtsmhavesomeerror
Bcreatebtshavesomeerror
Ccreatetrxhavesomeerror
DcreatechannelhavesomeerrorC
NO5.1
HereIgotonemessage“
CREATEBTS
NAME=BTSM:
15/BTS:
0:
RESP="INVALID_SVR"tryto
givethereasonpossibleabout
thisalarm.
Acreatepcmbhavesome
parameterseterror
Bcreatelapdmhavesome
parameterseterror
Ccreatebtsmhavesome
parameterseterror
Dcreatebtshavesome
parameterseterror
DNO5.1
HWMSC4OPCvalueisset1001(decimalpleasegiveacorrectvalueformatchSiemensdatabaseformat
(hex.
A10-10
B3-233
C1-1
D233-3D
YES4.3YES
HWMSC3SPCvalueisset
3000(decimalpleasegivea
correctvalueformatch
A8-187
B30-1
C11-184
D184-11
DYES4.3YES
whichparameterneedmodify
bySiemenssidewhenNTMSC
changesOPCvalue?
AOPC
BSPC
COMAL
DX25
BYES4.3YES
whichparameterneedmodifybySiemenssidewhenHWMSCchangesSPCvalue?
AOPC
BSPC
COMAL
DX25A
YES4.3YES
whichparameterneedmodify
bySiemenssidewhenNTMSC
changesSS7Llink
APCMA
BSS7L
CSPC
DNothingneedmodify
BYES4.3YES
TransferSiemensBSCtoHW
newMSC,whatparameter
mustbemodified.
ALACandCI
BTimerofT3212
CMelID
DOPCandSPC
DYES4.3YES
TransferSiemensBSCtoHWNTMSC,cannotmakeMTC,trytogivesomemethodoftechnicalfortroubleshooting.
AresetSS7L
BresetSP
CandOPC
CresetBSCsaluname
DrestartBSCS/WD
YES4.3YES
TransferSiemensBSCto
EricssonMSCallSS7Lcannot
working.Trytogivesome
probablymethodoftechnical
fortroubleshooting.
Areset“TSYNC”value
BresetBS
C“T3122”value
CresetBSC“MSCV”value
DresetBSC“saluname”
value
CYES4.3YES
TransferSiemensBSCtoHW
MSCsomesitecannotmake
MOC,trytogivesomemethod
oftechnicalforsolveproblem.
Areset“IMSIATDT”value
BresetBTSMversion
CrestartBTSS/W
DresetLACorCIvalueby
MSCside
DYES4.3YES
TransferSiemensBSCtoHWMSC;TheRCO-Linkcannotworkingnormally,trytogivesomemethodoftechnicalforsolveproblem.
ArestartTRAUS/W
BresetMELID
CresetBSC“NETWTYPE”value
DrestartRCserverB
YES4.3YES
currentnetworkconfiguration
asHWMSC1andHWBSC1、
SiemensBSC2aftertransfer
newSiemensBSC3to
HWMSC1,SiemensBSC3can
notmakehandoverto
HWBSC1exceptHWBSC1to
SiemensBSC3,trytogive
someadviceforsolvethis
problem.
ASiemensBSC3OPCand
SPCseterror
BNevercreatetargetcell
aboutadjacentcellintra
HWBSC1
CHWMSC1notcreate
externalhandoverdataabout
SiemensBSC3
DSiemensBSC3BTS
creationdatawasfail
CYES4.3YES
transferSiemensBSCtoNTMSCallMOCandMTCisworkingnowbutallincominghandover(interBSCwasrejectbyunknownreason.Whatdoyouthinkaboutthiscase?
ANTBSCparametersetincorrectness
BNTMS
Cparametersetincorrectness
CSiemensparametersetincorrectness
DTrunklinkshaveproblemB
YES4.3YES
AftertransferSiemensBSCto
HWMSCtheBSCO-Linkcan
notstart.TheO-Linkrouteis
firstSiemensBSCPCMA:
0-30
nuctoHWMSCthenfromHW
MSCnuctoSiemensown
MSC,atlastconnectiontoRC
server.pleasetrytogivesome
adviceforsolvethisproblem.
ASiemensBSCOMALorMEL
IDsetincorrectness
BHWMS
CNUCTSnot
correctwithSiemensMSC
CSiemensMSCNUCTCnot
correctwithRCsever
DAllpossibleabovereason
DYES4.3YES
机;
C:
\Documentsand
Settings\CN1LF110\Desktop\7.doc
在BSC的BFAP中只有与应的LED一直在闪烁,请给出完成的排除故障的操作步骤。
C:
\DocumentsandSettings\CN1LF110\Desktop\7.doc
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 认证 考试 题库 汇总 题目