特灵风管机技术参数图文精
技术参数涡旋机组制冷运行参数
室内机TWE075,室外机TWA075/TTA075
室内机TWE125,室外机TWA125/TTA125
室内回风室内回风
室外环境温度风量干球温度湿球温度
30°C35°C40°C45°C
总冷量
显热量
功率
总冷量
显热量
功率
总冷量
显热量
功率
总冷量
显热量
功率
m3
/h
°C°CkWkWkWkWkWkWkWkWkWkWkWkW211519.214.67.6518.414.28.5217.613.89.5016.713.310.59231619.815.67.7019.015.28.5718.214.79.5617.214.310.653600251720.416.57.7619.616.18.6318.815.79.6217.815.210.71271921.716.57.8720.916.18.7519.915.79.7318.915.210.82292123.116.37.9922.216.08.8721.215.69.8520.115.110.94211519.815.97.7019.015.48.5718.114.99.5517.214.410.64231620.416.97.7619.616.58.6318.716.09.6117.815.510.704400251721.118.07.8220.317.58.6919.417.19.6818.416.610.77271922.418.07.9321.517.68.8020.517.19.7919.516.610.88292123.818.08.0522.817.58.9221.717.19.9020.616.610.99211520.316.97.7419.416.48.6118.515.99.5917.615.410.68231620.918.17.8020.117.68.6819.217.29.6618.216.610.755200251721.719.37.8720.818.98.7419.918.49.7218.917.910.82271922.919.47.9822.018.98.8521.018.49.8319.917.910.92292124.319.48.0923.318.98.9622.218.49.9521.017.911.03211520.818.17.7919.917.78.6619.017.29.6418.016.610.72231621.519.57.8520.719.18.7319.718.69.7118.718.110.806300251722.320.97.9221.420.58.8020.520.09.7819.519.510.89271923.521.18.0222.620.68.9021.520.19.8820.419.610.97292124.821.18.1423.820.69.0122.720.210.0021.519.611.07
室内回风室内回风
室外环境温度风量干球温度湿球温度
30°C35°C40°C45°C
总冷量
显热量
功率
总冷量
显热量
功率
总冷量
显热量
功率
总冷量
显热量
功率
m3
/h
°C°CkWkWkWkWkWkWkWkWkWkWkWkW211530.521.611.9229.421.013.3428.220.414.9326.919.816.71231631.422.912.0430.322.313.4629.121.715.0727.721.016.854500251732.424.112.1731.223.613.6030.022.915.2128.622.216.99271934.423.912.4533.123.313.8931.822.715.5130.322.117.29292136.523.612.7435.123.114.1933.722.515.8232.121.817.60211531.723.412.0730.522.813.4929.222.115.0927.821.416.87231632.624.912.2031.424.213.6330.123.515.2328.722.717.015500251733.626.212.3432.425.513.7731.024.815.3829.624.117.16
27
1935.726.112.6234.325.514.0732.924.715.6731.324.017.46
292137.825.812.9236.325.214.3834.824.615.9933.123.817.76211532.624.912.2031.324.213.6130.023.515.2128.522.716.98231633.526.512.3332.325.813.7530.925.015.3629.424.317.136500251734.628.012.4833.327.313.9131.926.615.5230.325.817.29271936.628.012.7635.227.314.2033.726.515.8032.025.817.58292138.727.813.0537.227.114.5135.526.416.1233.825.617.89211533.426.612.3132.125.913.7330.725.115.3329.224.317.10231634.528.412.4633.127.613.8831.726.915.4930.226.117.267800251735.530.112.6134.229.414.0532.728.715.6531.228.017.43271937.530.112.8836.129.414.3434.528.715.9432.827.917.72292139.630.013.1938.129.314.6536.428.616.2534.627.818.02
机组外形尺寸图
TWE室内机组尺寸图(mm
TWE075/125
TWE150/250
卧式吊顶安装
型号TWE075TWE125A13721372B12071613C635635D300503
E607607
F408408P11471553R937937T560560X1818Y168168
型号TWE075TWE125AC406406AD4343AE10611468AF7373
AG7373AH10601468AJ178178
AK406406
型号TWE150TWE250A17511824B20192350C702773D282447
E14561456
F408408
P19602266
R12191291T660790W3042Y242242型号TWE150TWE250
AA891999
AB71124
AC8778
AD9076
AE891999
AF891999
AG96116AH18762105
AJ73122
AK457508
AN18762105
AP457508
AL891999
AM96116
直径22.23的过线孔(加热器控制线及单点电源线之预留孔
风口法兰
直径50.80的预留孔(吸气管—两边均有(最小尺寸供拆卸过滤网用(两端间距
直径22.23的预留孔(液管—两边均有
注:
a,b,c,d—直径22.23的预留孔(4处(卧式吊装
R
P
a
c
b
d
Y
C
F
E
D
A
T
W
B风口法兰T
(最小尺寸供拆卸过滤网用(两端间距
直径22.23的预留孔(液管—两边均有
直径22.23的预留孔(液管—两边均有直径22.23的过线孔(加热器控制线及单点电源线之预留孔
R
Y
a
b
d
c
C
F
B
E
D
A
P
直径50.80的预留孔(吸气管—两边均有W
AJAKAD
AF
AEAG
AH
回风口卧式回风
AB(特定尺寸
(特定尺寸
AA
ALAPAC
AM
AN风管口
回风口立式回风
回风口回风口卧式回风
AHAK
AJ
AG(特定尺寸
回风口回风口立式回风
ACAD
AEAF(特定尺寸
卧式吊顶安装
K354354X46117W3030XXK
风管口
机组外形尺寸图
TWE室内机组装配图及附件尺寸(mm
型号TWE075TWE125
TWE150TWE250
A1213161920262357
B642642
708780
热水盘管
电加热器
型号TWE075TWE125
TWE150TWE250
A1213161920262357
B642642708780
C737737889889
B
A
C
40
6A
B
TWE075,125
1-1/2"
318
761
410
31
8
1744
410
TWE150,250
MWD室内机组尺寸图(mm
主机
注:
标注尺寸单位mm
MWD机型只能右手接管
型号MWD075
MWD120
A398598
B450655
C9701095
D674797
E337399
M465670
133028
M-8
M
29
266
30
40
40
AA
B
C
56
A
1148
137
252
1148
118248
178.5
60
D
E
机组外形尺寸图
TWA/TTA室外机组尺寸图(mm
注:
为确保机组运行正常,距离灌木丛、栅栏等的最小距离为
915mm,邻近机组间的最小距离为1830mm。
B视图
最小间距为915mm
最小间距为915mm最小维修空间为1070mm
最小间距为915mm
B
A
控制箱
孔径45mm(高压10730.6
12368
22.23直径外突孔31.75吊装孔
D
38.1直径外突孔
孔径22.23mm(低压
顶部空间最小为2540mm
控制面板
压缩机维修面板
底脚直径11.11
KL
控制箱面板
A
B
最小间距为915mm
最小间距为915mm
最小间距为915mm
最小间距为915mm
B向A向
孔径45mm(高压
C
孔径22.23mm(低压
孔径38.1mm(冷媒压力表
38.1直径外突孔(吸气管
22.23直径外突孔(液管
A视图
D
顶部空间最小为2540mm
KL
C
型号TTA/TWA075TTA/TWA100,125
A10461300
B864
965C983
1137
D9851240
L762847
K644762
型号TTA/TWA150TTA/TWA200,250
A22402375
B8631118
C9831137
D21792313L762997
K644762