2.1MountingOptions………………………….........................................................................6
2.2BackboxMounting…………………………........................................................................6
2.3OperatingPower…………………………...........................................................................7
2.4InputCircuits………………………….................................................................................7
2.5OutputCircuits………………………….............................................................................8
CHAPTER3:
OperatingInstructions……………………………………................................9
3.1KeyFunctionsinNormalMode………………………….....................................................9
3.2StatusofLEDs…………………………............................................................................10
3.3Operation…………………………....................................................................................11
3.3.1FireAlarmResponse…………………………........................................................11
3.3.2FireAlarmRestoral………………………….......................................................12
3.3.3FaultConditionResponse…………………………............................................12
3.3.4FaultConditionRestoral…………………………...............................................12
ProductDescription
TheODH04isa1-zoneto4-zoneFACP(FireAlarmControlPanel),controlledbymicroprocessor,accordingtothecurrentnationalstandardGB4717-2005.Thepanelisabletobeconnectedwithconventionaltwo-wiresmokedetectors,two-wireheatdetectors,callpointsandothernormally-opencontactdevices.TheFACPsupervisesallwiring,ACvoltageandbatterylevel.
1.1ProductFeatures
●Connectedwithconventionaldetectorsandnormallyopencircuitdevice
●OneAlarmRelay
●OneTroubleRelay
●ManualCallpointalarm
●2.2ampsofsystempower
●Max30conventionaldetectorsinonezone
●Manualactivesoundoutputenabled.
●Abletodisplayshortandbrokencircuitofdetectionzones.
●Designedwithstandbybatteriesandspaceprovisionfortwosealedlead-acidbatteries.
●Testingfunctions.
FIGURE1.1:
ODH04CircuitBoard
1.2Specifications
ACPower
AC187V~AC242V50Hz±
1Hz
Battery(leadacidonly)
MaximumChargingCircuit:
NormalFlatCharge—27.6V@0.8amp
OutputDeviceCircuits
GeneralAlarmZones1through4
Operation:
Allzones
NormalOperatingVoltage:
Nominal28VDC
ShortCircuitCurrent:
42mAMaximum
MaximumLoopResistance:
100ohms
End-of-LineResistor:
5.1K,1/4watt
Detectorloopcurrentissufficienttoensureoperationoftwoalarmeddetectorsperzone
TwoRelaysoutput
Relaycontactrating:
1.0amps@28VDC(resistive)
Nonresettable28VDCPower
Maximumripplevoltage:
20mVRMSOperatingVoltagenominal:
28V
TotalDCcurrentavailablefromthisoutputisupto2.2A
OperatingEnvironment
Temperature:
0~55℃
Relativehumidity:
≤95%(40℃±
2℃)
Dimension:
370mmx240mmx60mm
1.3Controlandindicators
FrontPanelskeysinNormalMode
●
FUNCTION/ENTER
●SOUNDER
●SELFCHECK/+
●F1/—
RESET/
SILENCE
LEDs
●FIRE-redLED
●FAULT-yellowLED
●SYSTEMFAULT-yellowLED
●SELFCHECK-yellowLED
●SOUNDERINDICATE-redLED
●SOUNDERFAULT-yellowLED
●ACPOWER-yelloworgreenLED
●BATTERY-yelloworgreenLED
LocalSounder
Asounderprovidesseparateanddistinctsoundforfirealarmandtroubleconditions:
●FireAlarm-pulse0.3secondOnand0.3secondoff
●Fault-pulse0.8secondonand4secondoff
Figure1.3.1:
ODH04-4ZONELEDSandKeypad
Figure1.3.2:
ODH04-2ZONELEDSandKeypad
1.4Circuits
InputCircuits
4inputcircuitsprovideconfiguration.Inputcircuits1through4maybeusedasstandardfirealarm
controlpanelzones.All4initiatingdevicecircuitsacceptnormally-opencontactdevicesand
two-wiredetectors.
OutputCircuits
28VoltNonresettablePoweroutput1500mA
28VoltBatteryCharger(upto7AHbatteries)
RS-485Port(interfacestoAnnunciators)
SoundCircuits
OneNotificationApplianceCircuit
Relays
Twodryrelaysforsystemalarm,systemtroubleareprovidedstandard.Contactsarerated1.0amps@
28VDC(resistive)and1.0amps@110VAC(resistive).
RS-485Port
RS-485compatibleportsupportsupto4differentdeviceaddresseswhichcanconsistofremote
annunciators.
BatteryCharger
Batterychargerwillchargeupto2.2AHbatteries.heexternalboxisrequiredtohold7AH
batteries.Thechargerisratedfor500mAmaximumcurrent.
1.5Components
MainCircuitBoard
ThemaincircuitboardcontainsCPU,otherprimarycomponentsandwiringinterfaceconnectors.
Optionalmodulespluginandaremountedtothemaincircuitboard.Themaincircuitboardisdelivered
pre-mountedinthecabinet.
TerminalCircuitBoard
Theterminalcircuitboardcontains4inputcircuits,soundcircuits,wiringinterfaceconnectorsandother
primarycomponents,isdeliveredpre-mountedinthecabinet.
PowerSupplyCircuitBoard
ThePowerSupplycircuitboardcontainsbatterychargercircuit,ACpowersupplyandbatterytesting
circuitandwiringinterfaceconnectors,.
Cabinet
Thecabinetisblueandthebackboxmeasures370mmlongX240mmhighX600mmdeepandprovides
spacefortwobatteries(2.2AmpHours).
PowerModuleAssembly
One70VApowermoduleisprovidedstandardwiththepanel.
Batteries
Thecabinetprovidesspacefor2.2Amphourbatteries(largebatteriesupto7AmpHourbatteries,use
theexternalbatterybox).Batteriesmustbeorderedseparately.
Chapter2:
Installation
2.1MountingOptions
Thecabinetmaybeeithersemi-flushorsurfacemounted.Thecabinetmountsusingthreekeyholes.
Carefullyunpackthesystemandcheckforshippingdamage.Mountthecabinetinaclean,vibration-freeareawhereextremetemperaturesarenotencountered.Theareashouldbereadilyaccessiblewithsufficientroomtoeasilyinstallandmaintainthepanel.Locatethetopofthecabinetapproximatelyfivefeetabovethefloor.AllwiringshouldbeinaccordancewiththeNationaland/orLocalcodesforfirealarmsystems.
2.2BackboxMounting
✓Openthedoor
✓Markandpredrillholesforthetoptwokeyholemountingboltsusingthedimensionsillustrated.
✓Installtwoupperfastenersinthewallwiththescrewheadsprotruding.
✓Usingtwoupperkeyholes,mountthebackboxoverthetwoscrews.
✓Markanddrilltheloweroneholes.
✓Mountbackbox,installremainingfastenersandtighten.
Figure2-2-Cabinetdimensionsandknockoutlocations
2.3OperatingPower
PrimaryPowerSource(AC)
ACpowerconnectionsaremadeinsidethecontrolpanelcabinet.TheprimarypowersourcefortheODH04is220VAC,50Hz,2.2amps.ConnectpowersupplywiretotheCN1terminalofthepowersupplyboard.
SecondaryPowerSource(Batteries)
Observepolaritywhenconnectingthebattery.ConnectthebatterycabletotheCN3terminalofthepowersupplyboardusingtheplug-inconnectorandcableprovided.
Figure2-3:
Typicaloperatingpowerconnections
2.4InputCircuits
Thecontrolpanelhas1-4zoneinputcircuits.Themaximumloopresistancelimitforeachinputcircuitis100ohms.Allfieldwiringofeachzoneisdisplayedforfaults.Bothconditionsarevisuallyandaudiblyannunciated.
Eachzoneisadevicecircuitdesignedtoacceptanynormally-opencontactdevicesandconventional2-wire,28voltsmokedetectors.
Allzonesmaybeconfiguredforgeneralfirealarmapplications.
Itisallowabletomixanassortmentofdevicetypes(i.e.smokedetectors,heatdetectors,callpoints,etc.)onanyzone.
Figure2-4:
Initiatingdevicecircuitconnections
EndofLineResistor
DetectionZone
Base
2.5OutputCircuits
DCPowerOutputConnections
NonresettablePower(1500mA)28VDCfiltered,nonresettablepowercanbeobtainedfromterminal
28V(+)and(-).
Figure2-5-1:
NotificationApplianceCircuits
TheODH04providesonenotificationappliancecircuitstandard.Eachcircuitiscapableof2.0ampsofcurrent.TotalcurrentdrawnfromtheseaswellasotherDCpoweroutputcan’texceed2.2ampswiththestandardtransformer.Circuitsaresupervised.
StandardRelays
Thecontrolpanelprovidestworelaysratedfor1.0amps@28VDC(resistive)and1.0amps@120VAC(resistive)
Figure2-5-2:
Relayterminals
Chapter3:
OperatingInstructions
Figure3-1-1LedindicatorsandKeypad
Uponinitialpower-up,thesystemwillbeonNormalMode.Thissectiondiscussesoperationofthe
controlpanelintheNormalMode.
3.1KeyFunctionsinNormalMode
Figure3-1-2:
LedindicatorsandKeypad
Password"
119"
shouldbeentered.Press"
+"
and"
-"
toadjustthenumber.Press"
<
-"
->
"
tomovethecursor.PressFUNCTI