12.212andDFARSSection227.7202.
Logsforinstallerarebeingcreatedin/var/tmp/installer-4Xx9zQ.
StorageFoundationandHighAvailabilitySolutions5.0
SymantecProductVersionInstalledLicensed
===========================================================================
SymantecLicensingUtilitiesarenotinstalled.Unabletodetermineproductinstallationstatus.
TaskMenu:
I)Install/UpgradeaProductC)ConfigureanInstalledProduct
L)LicenseaProductP)PerformaPre-InstallationCheck
U)UninstallaProductD)ViewaProductDescription
Q)Quit?
)Help
EnteraTask:
[I,C,L,P,U,D,Q,?
]I
1)Veritas
2)VeritasVolumeManager
3)VeritasVolumeReplicator
4)VeritasStorageFoundation
5)VeritasStorageFoundationforOracle
6)VeritasStorageFoundationforDB2
7)VeritasStorageFoundationforSybase
8)VeritasStorageFoundationCluster
9)VeritasStorageFoundationforOracleRAC
10)SymantecProductAuthenticationService
b)Backtopreviousmenu
Selectaproducttoinstall:
[1-10,b,q]2
EnterthesystemnamesseparatedbyspacesonwhichtoinstallVxVM:
test1
Initialsystemcheck:
CheckingVxVMinstallationontest1.............................................................................................................notinstalled
Checkinginstalledpackagesontest1
VxVMcanbeinstalledwithoutoptionalpackagestoconservediskspace.
Additionalpackagesaretypicallyinstalledtosimplifyfutureupgrades.
1)RequiredVeritasVolumeManagerpackages-839MBrequired
2)AllVeritasVolumeManagerpackages-863MBrequired
3)StorageFoundationEnterprisepackages-1051MBrequired
Selectthepackagestobeinstalledonallsystems?
[1-3,q,?
](3)2
ThefollowingVxVMpackageswillbeinstalled:
VRTSperlVeritasPerl5.8.8Redistribution
VRTSvlicVeritasLicensing
VRTSicscoSymantecCommonInfrastructure
VRTSpbxSymantecPrivateBranchExchange
VRTSsmfSymantecServiceManagementFramework
VRTSatSymantecProductAuthenticationService
VRTSobc33VeritasEnterpriseAdministratorCoreService
VRTSobVeritasEnterpriseAdministratorService
VRTSobguiVeritasEnterpriseAdministrator
VRTSccgVeritasEnterpriseAdministratorCentralControlGrid
VRTSmhVeritasStorageFoundationManagedHostbySymantec
VRTSaaVeritasEnterpriseAdministratorActionAgent
VRTSsptVeritasSoftwareSupportTools
SYMClmaSymantecLicenseInventoryAgent
VRTSvxvmVeritasVolumeManagerBinaries
VRTSdsaVeritasDatacenterStorageAgent
VRTSfsproVeritasManagementServicesProvider
VRTSvmmanVeritasVolumeManagerManualPages
VRTSvmdocVeritasVolumeManagerDocumentation
Press[Return]tocontinue:
...continued:
VRTSdcliVeritasDistributedCommandLineInterface
VRTSallocVeritasVolumeManagerIntelligentStorageProvisioning
VRTSvmproVeritasVolumeManagerManagementServicesProvider
VRTSvsvcVeritasVolumeServerandClientProvider
VRTSvdidVeritasDeviceIdentificationAPI
VRTSddlprVeritasDeviceDiscoveryLayerServicesProvider
VRTSvrproVeritasVolumeReplicatorClientExtensionandProviderfor
VeritasEnterpriseAdministrator
VRTSvcsvrVeritasClusterServerAgentsforVVR
VRTSjreVeritasJavaRuntimeEnvironmentRedistribution
VRTSjre15VeritasJavaRuntimeEnvironmentRedistribution
VRTSwebVeritasJavaWebServer
VRTSvrwVeritasVolumeReplicatorWebConsole
VRTSvrdocVeritasVolumeReplicatorDocumentation
CheckingforanyAPdriverissuesontest1...............................................................................................................None
InstallingVxVM:
100%
Installationcompletedsuccessfullyonallsystems
Checkingsystemlicensing
VxVMisnotlicensedontest1
EnteraVxVMlicensekeyfortest1:
3JZG-WUMV-U43N-RRI9-EP36-PZPD-P
3JZG-WUMV-U43N-RRI9-EP36-PZPD-Psuccessfullyregisteredontest1
PermanentVxVMlicenseregisteredontest1
Doyouwanttoenteranotherlicensekeyfortest1?
[y,n,q](n)n
ItisoptionaltoconfigureVxVMnow.IfyouchoosetoconfigureVxVMlater,youcaneitherdosomanuallyorruntheinstallvm-configurecommand.
AreyoureadytoconfigureVxVM?
[y,n,q](y)n
二、VXVM配置DG
1、确定磁盘对应关系
确定vxvm管理磁盘跟物理磁盘对应关系
bash-3.2#format
Searchingfordisks...done
AVAILABLEDISKSELECTIONS:
0.c0t0d0<
SUN72Gcyl14087alt2hd24sec424>
/pci@1c,600000/scsi@2/sd@0,0
1.c0t1d0<
/pci@1c,600000/scsi@2/sd@1,0
2.c1t202600A0B8744C8Ad0<
IBM-1726-4xxFAStT-0617cyl5118alt2hd64sec64>
/pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w202600a0b8744c8a,0
3.c1t202600A0B8744C8Ad1<
IBM-1726-4xxFAStT-0617cyl5630alt2hd64sec64>
/pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w202600a0b8744c8a,1
4.c1t202600A0B8744C8Ad2<
IBM-1726-4xxFAStT-0617cyl6654alt2hd64sec64>
/pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w202600a0b8744c8a,2
5.c1t202600A0B8744C8Ad3<
/pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w202600a0b8744c8a,3
6.c1t202600A0B8744C8Ad4<
drivetypeunknown>
/pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w202600a0b8744c8a,4
7.c1t202700A0B8744C8Ad0<
/pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w202700a0b8744c8a,0
8.c1t202700A0B8744C8Ad1<
/pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w202700a0b8744c8a,1
9.c1t202700A0B8744C8Ad2<
/pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w202700a0b8744c8a,2
10.c1t202700A0B8744C8Ad3<
/pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w202700a0b8744c8a,3
11.c1t202700A0B8744C8Ad4<
/pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w202700a0b8744c8a,4
Specifydisk(enteritsnumber):
bash-3.2#vxdiskpath
SUBPATHDANAMEDMNAMEGROUPSTATE
c1t202600A0B8744C8Ad0s2Disk_2--ENABLED
c1t202600A0B8744C8Ad3s2Disk_3--ENABLED
c1t202600A0B8744C8Ad1s2Disk_4--ENABLED
c1t202600A0B8744C8Ad2s2Disk_5--ENABLED
c1t202600A0B8744C8Ad4s2Disk_6--ENABLED
c1t202600A0B8744C8Ad4s2Disk_11--ENABLED
c1t202700A0B8744C8Ad2s2Disk_12--ENABLED
c1t202700A0B8744C8Ad3s2Disk_12--ENABLED
c1t202700A0B8744C8Ad0s2Disk_12--ENABLED
c1t202700A0B8744C8Ad1s2Disk_12--ENABLED
c0t0d0s2c0t0d0s2--ENABLED
c0t1d0s2c0t1d0s2--ENABLED
2、初始化磁盘
bash-3.2#vxdisklist
DEVICETYPEDISKGROUPSTATUS
Disk_2auto:
cdsdisk--onlineinvalid
Disk_3auto:
none--onlineinvalid
Disk_4auto:
Disk_5auto:
Disk_6auto:
Disk_7auto--error
Disk_8auto--error
c0t0d0s2auto:
c0t1d0s2auto:
bash-3.2#vxdiskinitDisk_2
bash-3.2#vxdiskinitDisk_3
bash-3.2#vxdiskinitDisk_4
bash-3.2#vxdiskinitDisk_5
bash-3.2#vxdiskinitDisk_6
cdsdisk--online
3、制作DG
bash-3.2#vxdginitvxdgvxdgn01=Disk_2
cdsdiskvxdgn01vxdgonline
4、DG中添加磁盘
bash-3.2#vxdg-gvxdgadddiskvxdgn02=Disk_3
bash-3.2#vxdg-gvxdgadddiskvxdgn03=Disk_4
bash-3.2#vxdg-gvxdgadddiskvxdgn05=Disk_5
bash-3.2#vxdg-gvxdgadddiskvxdgn06=Disk_6
bash-3.2#vxdisklist
cdsdiskvxdgn02vxdgonline
cdsdiskvxdgn03vxdgonline
cdsdiskvxdgn05vxdgonline
cdsdiskvxdgn06vxdgonline
5、查看DG大小
bash-3.2#vxassist-gvxdgmaxsize
Maximumvolumesize:
119166976(58187Mb)
6、DG中删除磁盘
(1)直接用命令移除
bash-3.2#vxdg–gvxdgrmdiskvxdgn01
bash-3.2#vxdg–gvxdgrmdiskvxdgn02
bash-3.2#vxdg–gvxdgrmdiskvxdgn03
bash-3.2#vxdg–gvxdgrmdiskvxdgn04
bash-3.2#vxdg–gvxdgrmdiskvxdgn05
Disk