R1系统散热器计算立管编号层数热负荷热负荷供水温度回水温度室温1511850185075.050.05.01850612000200075.050.05.02000712000200075.050.05.02000附加系数散热量/片片片数数调调整整片片数数型型号号调调整整片片数数每每层层片片数数100%99.019.622020多柱钢管柱散热器GGZ3-III-600(3柱)200105%99.021.212323多柱钢管柱散热器GGZ3-III-600(3柱)230105%99.021.212323多柱钢管柱散热器GGZ3-III-600(3柱)230R1系统散热器计算立管编号层数热负荷热负荷供水温度回水温度室温附加系数散热量/片片片数数调调整整片片数数型型号号调调整整片片数数每每层层片片数数第4页,共31页R2系统散热器计算立管编号层数热负荷热负荷供水温度回水温度室温附加系数散热量/片片片数数调调整整片片数数型型号号调调整整片片数数每每层层片片数数1-61-6,17-2017-204层0075.075.018.095%97.90.0000多柱钢管柱散热器GGZ3-III-600(3柱)00651003733层2000200075.067.318.0105%89.623.43252524.601712502层2000200067.359.618.0105%73.528.56303029.989193001层2510251059.650.018.0110%56.246.86525251.5494752774层2200220075.066.118.0105%88.426.142828多柱钢管柱散热器GGZ3-III-600(3柱)27.4513528620003553层2000200066.158.118.0105%70.729.70323231.18733202层2000200058.150.018.0105%54.738.38414140.298474101层0050.050.018.095%47.10.0000008,22,268,22,264层075.075.018.095%97.90.0000多柱钢管柱散热器GGZ3-III-600(3柱)00370002123层1000100075.068.218.095%90.611.59111111.007841102层1200120068.260.118.0100%75.016.80171716.803131701层1500150060.150.018.0105%56.727.77303029.156663021214层2200220075.067.418.0105%89.725.762727多柱钢管柱散热器GGZ3-III-600(3柱)27.0484527720004133层1500150067.462.218.0105%76.220.68222221.714842202层1500150062.256.918.0105%65.624.02262625.2256926第5页共31页01层2000200056.950.018.0105%53.639.15424241.107564223-2523-254层2200220075.068.718.0105%91.125.362727多柱钢管柱散热器GGZ3-III-600(3柱)26.6270327871004993层2000200068.762.918.0105%78.426.80292928.142412902层2000200062.957.218.0105%66.631.53343433.101553401层2510251057.250.018.0110%53.948.91545453.7964154多柱钢管柱散热器GGZ3-III-600(3柱)2层1500第6页共31页长阳3-3热负荷计算房间名称维护结构名称计算传热系数传热系数面积室内温度室外温度附加系数耗耗热热量量考虑间歇调节x1.2负负荷荷统统计计一层北外墙0.60.6108.0018-10.60%18531853产品展示区(左)北外窗2.862.8625.2018-10.60%20612061窗缝79.8018-10.6325612561南外墙0.420.42113.4018-10.6-25%10221022南外窗2.862.8621.6018-10.6-25%13251325窗缝66.6018-10.6214251425南外门3312.4218-10.6-25%799799门缝21.9018-10.64937937门冷风侵入3312.4218-10.665%693693通风6750.0018-10.60.12590279027屋面0.600.60500.0018-10.60地面0.470.47500.0018-10.60672167212842528425341103411034110试验室主厂房热指标68.21927908一层北外墙0.60.655.4418-10.60%951951产品展览区北外窗2.862.8616.5618-10.60%13551355窗缝45.6018-10.6314641464南外墙0.420.42101.8818-10.6-25%918918南外窗2.862.8633.1218-10.6-25%20322032窗缝98.4018-10.6221062106南外门3332.2018-10.6-25%20722072门缝29.1018-10.6412451245门冷风侵入3332.2018-10.665%17961796通风8397.0018-10.60.1251123011230屋面0.600.60622.0018-10.60地面0.470.47622.0018-10.60836183613352833528402344023440234试验室主厂房热指标64.68491906一层北外墙0.60.666.9618-10.60%11491149加工间北外窗2.862.8616.5618-10.60%13551355第7页共31页【3-3采暖热负荷计算书】长阳3-3热负荷计算窗缝45.6018-10.6314641464北外门336.4818-10.60%556556门缝15.9018-10.6610211021门冷风侵入336.4818-10.665%361361通风1836.0018-10.60.12524552455屋面0.600.60153.0018-10.60地面0.470.47153.0018-10.60205720571041710417125011250112501试验室主厂房热指标81.70320949一层北外墙0.60.655.0818-10.60%945945产品展示(右)北外窗2.862.8612.4218-10.60%10161016窗缝34.2018-10.6310981098南外墙0.420.4229.7918-10.6-25%268268南外窗2.862.8627.0018-10.6-25%16561656窗缝36.9018-10.62790790南外门336.2118-10.6-25%400400门缝15.9018-10.64680680门冷风侵入336.2118-10.665%346346通风3145.5018-10.60.12542074207屋面0.600.60233.0018-10.60地面0.470.47233.0018-10.60313231321453814538174461744617446试验室主厂房热指标74.87398938一层北外墙0.60.620.7016-10.60%330330卫生间北外窗2.862.865.4016-10.60%411411窗缝19.8016-10.63591591通风348.0016-10.60.125433433屋面0.600.6029.0016-10.60地面0.470.4729.0016-10.6036336321282128255325532553试验室主厂房热指标88.04067853一层南外墙0.420.42114.3016-10.6-25%958958门厅南外窗2.862.8620.7016-10.6-25%11811181窗缝77.4016-10.6215401540第8页共31页【3-3采暖热负荷计算书】长阳3-3热负荷计算南外门3312.4216-10.6-25%743743门缝21.9016-10.64872872门冷风侵入3312.4216-10.665%644644通风3618.0016-10.60.12545004500屋面0.600.60268.0016-10.60地面0.470.47268.0016-10.60335133511378913789165471654716547试验室主厂房热指标61.74193556一层北外墙0.60.653.4018-10.60%916916楼梯间北外窗2.862.8621.6018-10.60%17671767窗缝68.4018-10.6321952195通风276.0018-10.60.125369369屋面0.600.6023.0018-10.60地面0.470.4723.0018-10.6030930955575557666866686668试验室主厂房热指标289.9189103二层北外墙0.60.6108.0018-10.60%18531853展示区北外窗2.862.8625.2018-10.60%20612061窗缝79.8018-10.6325612561南外墙0.420.42113.4018-10.6-25%10221022南外窗2.862.8621.6018-10.6-25%13251325窗缝66.6018-10.6214251425南外门3312.4218-10.6-25%799799门缝21.9018-10.64937937门冷风侵入3312.4218-10.665%693693通风6750.0018-10.60.12590279027屋面0.600.60500.0018-10.60地面0.470.47500.0018-10.602170421704260442604426044试验室主厂房热指标52.08887908二层南外墙0.420.4278.6618-10.6-25%709709公共食堂(小)南外窗2.862.8624.8418-10.6-25%15241524第9页共31页【3-3采暖热负荷计算书】长阳3-3热负荷计算窗缝73.8018-10.6215791579通风4194.0018-10.60.12556095609屋面0.600.60233.0018-10.60地面0.470.47233.0018-10.60313231321255212552150631506315063试验室主厂房热指标64.64758946二层北外墙0.60.6129.2418-10.60%22182218公共食堂(大)北外窗2.862.8637.2618-10.60%30483048窗缝45.6018-10.6314641464通风4160.0018-10.60.12555635563屋面0.600.60260.0018-10.60地面0.470.47260.0018-10.60349534951578715787189451894518945试验室主厂房热指标72.86444141二层东外墙0.420.4212.6018-10.6-10%136136休息区南外窗2.862.8627.0018-10.6-25%16561656窗缝36.9018-10.62790790通风837.0018-10.60.12511191119屋面0.600.6062.0
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 暖通 项目 采暖 负荷 详细 计算 内部