整理尚洁六合一甲醛检测仪器甲醛测试仪测试室内污染气体Shangjiehexaformaldehydetestinginstru
尚洁六合一甲醛检测仪器甲醛测试仪测试室内污染气体(Shangjiehexaformaldehydetestinginstrumentformaldehydetestertestsindoorpollutiongas)
Hello!
Thankyouverymuchforchoosingourproducts!
Toensurethatyouhavebettersecurityandeffectivenessinyouruse,pleasenotethefollowing:
Pleasereadtheinstructionscarefullybeforeusingtheinstrumenttomakesureyouareabletooperateproperly.
Ourinstrumentsaredesignedtobeabletocarryandspotfastdetectionasitsmainfeatures,andthequalityandsafetyofthetestedsampleswillbeabletoachieverapidfielddetection.Thetestresultscanbeusedasthebasicreferencedataofthelegaldecision.
3.Thereagentusedintheinstrumentisachemicalmedicine,whichabsolutelyprohibitschildrenandnon-personnelfromcontactingreagents.
4.Instructionsforuseofinstruments:
Whenthetestisover,alltheequipmentandequipmentmustbeturnedoff,soasnottooccur.
Payattentiontotheconnectionbetweentheabsorptionbottleandtheinstrument,preventthebackfill,damagetheinstrument.
Takecareofthepositionofthehosebeforestartingtheinstrumentandavoidtouchingthegroundtopreventtheforeignbodyfrominhaling.
Donotallowtheairpumptobeinworkforlongperiodsoftimewithouttrafficortraffic
Machinelife.
Maintainyourequipmentlevelwhileworking.
Preventtheinstrumentfromvibratingviolently.
6.Payattentiontotheinjuredhandwhilecuttingthetube,andtheglassresidueshouldbeproperlyhandled.
Balancewhenusingtripod.
7.Samplepointrequirements
Roomslessthan50m2shouldbeset(1-3);50m2-100m2(3-5);Atleast5pointsabove100m2,evenlydistributedondiagonalorplum.
Theheightofthesamplingpointisinlinewiththeheightoftheperson'sbreathingbelt,whichisbetween0.5and1.5m.
8.Samplingmethod
ClosedoorsandWindows12hoursbeforesamplingandclosedoorsandWindowswhensampling.
Theinstrumentfeatures
Multi-function:
candetectformaldehyde,benzene,ammonia,toluene,xylene,TVOCharmfulgasinindoorair.
Bringflowstability:
inordertomeettheneedsoftheindoorenvironmentmonitoring,theinstrumentadoptsthelargeflowpump,adjustableresistancemeter,steadyflow,thecharacteristicsofhighprecision,canwelladapttobenzene,ammonia,suchastoluene,xylene,TVOCtesttubehasalargersamplingresistance;
Automaticcontrol:
cansetthetimein0~99minutes,easytooperateandintuitive.Setsamplingtimeatthecontrolpanelandautomaticallystopworkingwhenthesampleisfinished.Thetimeaccuracyishigh,thesamplingerrorisnotmorethan0.1second;
Temperatureandhumiditydirections:
thetemperatureandhumidityofthedetectionsitecanbedisplayedonthepanel,whichcandirectlyreflecttheenvironmentalconditionsofthesamplingsite(optional).
Theformaldehydecontentwasmeasuredatthesite.
Theabove-limitsound,lightalarmprompt.
Thetestreportofthecustomizedformatoftheon-sitethermalprinting(optional).
Lightweight:
smallsize,lightweight,easytocarry.
Powersupply:
220Vac,strong,weakandindependent.
Packaging:
theouterpackingoftheinstrumentisasmallaluminumalloysuitcase.
Samplebracket:
anothertripodisequippedtoadjustthesamplingheight.
Technicalindicators
1.Testitems:
formaldehyde,benzene,ammonia,toluene,xylene,TVOC
2.Measuringrange:
Formaldehyde(0.01~1.2mg/m3)
Benzene(0.05~4mg/m3)
Ammonia(0.05~3mg/m3)
Toluene(0.05~4mg/m3)
Xylene(0.05~4mg/m3)
TVOC(0.05~4mg/m3)
3.Flowrange:
flow6X2.
5litresperminute
4.Lightsource:
LEDsiliconphotodiode,wavelengthof630nm
5.Accuracy:
plusorminus10%reading,formaldehydemeasurementaccuracyislessthan5%.
6.Testreportofthecustomizedformatoftheon-sitethermalprinting.
7.Flowstability:
>95%
8.Timedcontrol:
0--99minutes
Power:
6X6watts
10.Power:
220Vac
11.Mainframesize:
340x260x145(mm)
12.Weight:
4kg
13.Bluebackgroundlightfortheuseofdarkweather
14.Sixgasescanbedetectedatthesametime
Instrumentoperation
Instrument'sfrontpanelisdividedintoregularoperationflowcontrolarea,formaldehyde,formaldehydedeterminationofthreeparts,throughtheregularoperationcanbeseteachtimetochecktheprojectneed,thedetectionofformaldehydecanturnleftandrightadjustmentmeteratthebottomofthecircularknobandtoadjustthedetectionofformaldehydeinairbyquantityperminute,determinationofformaldehydeareathroughtheoperationcanformaldehyde,zerosensor,dataprinting,etc.
Themachine'srearpanelpowerswitchandthepowersupplyplugwireinterfaceandhangsTaiwanglassbubbleabsorptiontubebracketscrew,testprograminterface,inorderfromrighttoleft:
formaldehyde,benzene,ammonia,toluene,xylene,TVOC.Theleftsideofthemachineisabuilt-inthermalprinterthatcanprintcustomformaldehydetestreports.
Resettingtoavoidtheairpumpidlingoftheprojectthatdoesnotneedtobetested,whichaffectstheservicelifeofthemachine.
Formaldehydedetectionoperation:
Transferabsorptionfluid:
pourtheabsorbedfluidintotheglass.
Connecttotheinstrument:
theglassabsorptionbottleisputonthedeviceholder,therubberhoseconnectiontotheinstrument(theformaldehydeinterface),theconnectionmethodisasabove
Note:
itcan'tbereversed,otherwiseitwillcausethesuctionanddamagetotheinstrument.
Placetheinstrumenttotheheightofthebreathingzone(0.8-1.5m)anduseatripodorahighlysuitabletable(forexample,indoorairtest).
Connectthepoweroftheinstrumentandfollowthe"timedoperation"methodtoperformtimingoperation:
Fourdigitaltube,inorderfromlefttoright:
thefirstistheprojectarea,showthenumber1-6,inturn,correspondingtothecorrespondingtestitems,1-,3-2-benzene,ammonia,formaldehyde,4-toluene,5-,6-TVOC,xylenesetsamplingtime,samplingtime10minutes(flow1litres/minute,samplingof10litres,undertheconditionofthesamplingvolumecanadjusttimeandtraffic).
Press"start/stop"button,theinstrumentstartswork,workindicatorlight.
Adjusttheflowassetvalue(adjusttheadjustingknobbelowtheflowmeter).
Automatictimingofinstrument,automaticstop,workindicatorlightout.
Combinetheabsorbingliquidwiththeliquidandleavefor15minutes.
Atthistime,theliquidshowsthecolor,andthecolorofthedisplaycolorafterthecolorisputintothemachine'scolorimetricslot,andthecorrespondingoperationofformaldehydedeterminationandprintingiscarriedout.(specificoperationpleaseseetheformaldehydedeterminationoperation)
Note:
Theflowmeterreadingisbasedonthecenteroftherotor,andiftherotormovesupanddown,thecenterofthefluctuationcenterreads.
Benzenedetectionoperation:
Removethebenzenedetectiontubeandopentheendoftheglassdetectiontube.
Fixthetesttubetothecorrespondinginterfaceatthebackoftheinstrument.
Thehighendofthetesttubeisconnectedwiththehoseofthesampler(benzeneinterface),andthearrowonthedetectiontubeisinthedirectionofairflow.
Connecttoseal,donotleakgas.
Accordingto"generaltimingoperation"methodtoperformtimingoperation,setsamplingtime.
Press"start/stop"button,theinstrumentwillstartworking,blueworkindicatorlight.
Theinstrumentstartstoclockandstopsworkingautomaticallyaftersettingtime.
Takeoffthetesttubeandreadthescaleofthediscolorationsection(ifthereisnocolorchange,thebenzeneconcentrationintheairisverylow,smallerthanthedetectionlimitofthedetector).
Ammonia,toluene,xylene,TVOCdetectionoperation(detectionmethodandbenzene)formaldehydedeterminationoperation
Datatodetermine
Themachinehasthreebeepswhenthemachineisturnedon,andthenthedigitaltubedisplays"0.00"whenthesensorisinthereadystate.
Willshowacolorwiththeabsorptionoffluidinthetubeintothemachineatthetopofthetankthancolor,andthenpressthe"test"key,digitaldistrictwillappearthecorrespondingtestingdata,suchas"0.12",ifthetestingdatabeyondtheGB/T18883-2002,limitedtoformaldehyde,themachinewillalarmbeeping,redalarmgoesonatthesametime,ifthetestingdataovertheinstrumentdetectionlimitthedigitaltubedisplays"1"andhaveasoundandlightalarmprompt.
Digitalprinting(optional):
districttodisplayaftertestingdata,pressthe"P"keyatthistimeaccordingtotheformatofthecustomprintoutthetestdata,andautomaticallyaccordingtotheGB/T18883-2002limitedjudgmentofformaldehydeinthetestresultsarequalified.
Note:
thesampleisrecommendedtobemeasuredatabout10secondsforeachsample,sothatthemachinecanbereset.
Sensorzero
Putthetubeinthetopofthemachinewithatransparentabsorbenttube,thenholdthe"zero"buttonforabout6seconds,whenthesensorisresetandthenewzerostatedataiswrittentothechip.Ifthezeroliquidisputinthemaximumrangebeforethefactoryisplaced,thenthedigitaltubewilldisplayanerrormessageof"E-".
Thedatatoadjust
Thismachinehasbeforetheygooutofthemachineaccordingtostandardvalueofthesensorcalibration,butinactualusebecauseofchangesintheenvironmentandsensorsintheprocessofagingorthespecialneedsofuserscanbeadjustedtothestandardofdata.
Keydefinition:
theredbuttonofthebackpanelis"set".
Key,the"determination"keyofthemeasurementareais"increase"key,the"setzero"keyinthemeasurementareais"reduce"key.
Datasegmentdefinition:
theinstrumenthasarangeof0to1.2
Mg/m3,thedataisdividedinto1-6paragrap
- 配套讲稿: