兰成渝成品油管道成都站停电分析报告
"",站名,压力I/O(MPa),压降(MPa),温度I/O(℃),温降(℃),粘度I/O(mPa.s),地温(℃),k
0:
兰州首站,0.20/4.46,"",11.80/12.00,"",5.91/5.91,11.40,1.30
1:
截断阀1,142.32/142.32,-137.86,11.92/11.92,0.08,5.91/5.91,11.66,1.30
2:
临洮分输泵站,139.91/149.35,2.40,11.91/11.91,0.01,5.91/5.91,12.08,1.30
3:
截断阀2,147.77/147.77,1.58,12.07/12.07,-0.16,5.91/5.91,12.65,1.30
4:
陇西分输站,148.63/148.63,-0.86,12.15/12.15,-0.08,5.91/5.91,12.83,1.30
5:
截断阀3,149.46/149.46,-0.83,12.33/12.33,-0.17,5.91/5.91,13.15,1.30
6:
截断阀4,145.93/145.93,3.53,12.67/12.67,-0.34,5.91/5.91,13.66,1.30
7:
截断阀5,147.84/147.84,-1.90,13.05/13.05,-0.39,5.91/5.91,14.16,1.30
8:
成县减压分输站,149.68/149.68,-1.84,13.14/13.14,-0.09,5.91/5.91,14.27,1.30
9:
截断阀6,146.83/146.83,2.85,13.47/13.47,-0.33,5.91/5.91,14.63,1.30
10:
截断阀7,150.12/150.12,-3.29,14.06/14.06,-0.60,5.91/5.91,15.26,1.30
11:
截断阀8,150.11/150.11,0.00,14.11/14.11,-0.05,5.91/5.91,15.31,1.30
12:
广元减压分输站,149.50/149.50,0.61,14.46/14.46,-0.35,5.91/5.91,15.67,1.30
13:
截断阀9,149.48/149.48,0.02,14.55/14.55,-0.09,5.91/5.91,15.77,1.30
14:
截断阀10,149.50/149.50,-0.02,14.61/14.61,-0.06,5.91/5.91,15.83,1.30
15:
截断阀11,145.89/145.89,3.61,14.95/14.95,-0.34,5.91/5.91,16.18,1.30
16:
江油清管站,146.50/146.50,-0.61,15.37/15.37,-0.42,5.91/5.91,16.61,1.30
17:
绵阳分输站(截断阀),145.15/145.15,1.35,15.66/15.66,-0.29,5.91/5.91,16.93,1.30
18:
德阳分输站,143.89/143.89,1.27,16.04/16.04,-0.38,5.91/5.91,17.34,1.30
19:
截断阀12,143.24/143.24,0.65,16.15/16.15,-0.11,5.91/5.91,17.46,1.30
20:
彭州分输站,142.18/142.18,1.06,16.34/16.34,-0.19,5.91/5.91,17.65,1.30
21:
成都分输泵站,141.62/152.19,0.56,16.49/16.49,-0.15,5.91/5.91,17.81,1.30
22:
简阳分输站,142.72/142.72,9.47,16.93/16.93,-0.44,5.91/5.91,18.36,1.30
23:
资阳分输站,142.23/142.23,0.49,17.23/17.23,-0.30,5.91/5.91,18.55,1.30
24:
截断阀13,140.89/140.89,1.34,17.54/17.54,-0.31,5.91/5.91,18.76,1.30
25:
内江分输泵站,138.88/148.21,2.01,18.08/18.08,-0.54,5.91/5.91,19.17,1.30
26:
截断阀14,148.14/148.14,0.07,18.22/18.22,-0.14,5.91/5.91,19.28,1.30
27:
隆昌分输站,146.21/146.21,1.92,18.50/18.50,-0.28,5.91/5.91,19.51,1.30
28:
永川分输站,143.43/143.43,2.78,19.12/19.12,-0.62,5.91/5.91,20.06,1.30
29:
重庆末站,142.13/142.13,1.30,19.59/19.59,-0.47,5.91/5.91,20.50,1.30
温度分布
初始状态(压力表示)
初始状态(水头表示)
结束状态(压力表示)
结束状态(水头表示)
最大最小压力(时间)
最大最小压力
各站点进出站压力及流量曲线
0号站(兰州首站)进出站压力及流量曲线:
1号站(截断阀1)进出站压力及流量曲线:
2号站(临洮分输泵站)进出站压力及流量曲线:
3号站(截断阀2)进出站压力及流量曲线:
4号站(陇西分输站)进出站压力及流量曲线:
5号站(截断阀3)进出站压力及流量曲线:
6号站(截断阀4)进出站压力及流量曲线:
7号站(截断阀5)进出站压力及流量曲线:
8号站(成县减压分输站)进出站压力及流量曲线:
9号站(截断阀6)进出站压力及流量曲线:
10号站(截断阀7)进出站压力及流量曲线:
11号站(截断阀8)进出站压力及流量曲线:
12号站(广元减压分输站)进出站压力及流量曲线:
13号站(截断阀9)进出站压力及流量曲线:
14号站(截断阀10)进出站压力及流量曲线:
15号站(截断阀11)进出站压力及流量曲线:
16号站(江油清管站)进出站压力及流量曲线:
17号站(绵阳分输站(截断阀))进出站压力及流量曲线:
18号站(德阳分输站)进出站压力及流量曲线:
19号站(截断阀12)进出站压力及流量曲线:
20号站(彭州分输站)进出站压力及流量曲线:
21号站(成都分输泵站)进出站压力及流量曲线:
22号站(简阳分输站)进出站压力及流量曲线:
23号站(资阳分输站)进出站压力及流量曲线:
24号站(截断阀13)进出站压力及流量曲线:
25号站(内江分输泵站)进出站压力及流量曲线:
26号站(截断阀14)进出站压力及流量曲线:
27号站(隆昌分输站)进出站压力及流量曲线:
28号站(永川分输站)进出站压力及流量曲线:
29号站(重庆末站)进出站压力及流量曲线:
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 兰成渝 成品油 管道 成都 停电 分析 报告