最新耦合器测试报告
TESTREPORT
IEC60320-1and/orEN60320-1
Appliancecouplersforhouseholdandsimilargeneralpurposes
Part 1:
Generalrequirements
ReportreferenceNo.:
Testedby
(printednameandsignature):
Approvedby
(printednameandsignature):
Dateofissue:
TestingLaboratoryName:
Address:
Testinglocation/procedure:
CBTLSMTTMP
Address:
Applicant’sName:
Address:
Testspecification
Standard:
IEC60320-1:
2001and/orEN60320-1:
2001
Testprocedure:
CBand/orCCAScheme
Non-standardtestmethod:
TestReportFormNo.:
IECEN60320_1D
TRForiginator.:
IMQ
MasterTRF:
Dated02-02
Copyright©2002IECSystemforConformityTestingandCertificationofElectricalEquipment
(IECEE),Geneva,Switzerland.Allrightsreserved.
Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongastheIECEEisacknowledgedascopyrightownerandsourceofthematerial.IECEEtakesnoresponsibilityforandwillnotassumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoitsplacementandcontext.
Testitemdescription:
Trademark:
Manufacturer:
Modeland/ortypereference:
Rating(s):
Copyofmarkingplate
Summaryoftesting
Testitemparticulars:
Connector:
Yes/No
...whichis:
rewirable/non-rewirable
Applianceinlet:
Yes/No
...whichis:
integrated/incorporated
For:
coldconditions/hotconditions/veryhotconditions
For:
Class Iequipment/Class IIequipment
Earthingcontact:
with/without
Typeofterminal:
pillar/screw/stud/screwless
Typeofcord:
Cross-sectionalareas(mm²):
Voltage(V):
Current(A):
StandardSheet:
C
Possibletestcaseverdicts:
Testcasedoesnotapplytothetestobject:
N/A
Testitemdoesmeettherequirement:
Pass(P)
Testitemdoesnotmeettherequirement:
Fail(F)
Testing
Dateofreceiptoftestitem:
Date(s)ofperformanceoftest:
Generalremarks
ThistestreportisnotvalidasaCBTestReportunlesssignedbyanapprovedCBTestingLaboratoryandappendedtoaCBTestCertificateissuedbyaNCBinaccordancewithIECEE02.
Thetestresultspresentedinthisreportrelateonlytotheitem(s)tested.
Thisreportshallnotbereproducedexceptinfullwithoutthewrittenapprovalofthetestinglaboratory.
”(seeremark#)"referstoaremarkappendedtothereport.
”(seeAnnex#)"referstoanannexappendedtothereport.
"(seeappendedtable)"referstoatableinthereport.
Throughoutthisreportacommaisusedasthedecimalseparator.
IEC60320-1and/orEN60320-1
Clause
Requirement-Test
Result-Remark
Verdict
8
MARKING
8.1
Connectorsmarkedwith:
-ratedcurrent(A) :
-ratedvoltage(V) :
-symbolfornatureofsupply :
-maker'sorresponsiblevendor'snameortrademark :
-typereference :
8.2
Applianceinletsmarkedwith:
-maker'sorresponsiblevendor'snameortrademark :
-typereference(notvisible) :
8.3
ConnectorsandapplianceinletsforClass IInotmarkedwithsymbolforClass II
8.4
Correctsymbolsused
8.5
Markingeasilydiscernible
8.6
Contactpositioninnon-reversibleconnectorsshallbe:
-earthingcontact:
uppercentralposition
-linecontact:
lowerrighthandposition
-neutralcontact:
lowerlefthandposition
Indicationofterminalsinrewirablenon-reversibleconnectorsshallbe:
-earthingterminal:
[earthsymbol]:
-neutralterminal:
N :
Markingnotonremovableparts
Rewirableconnectors:
supplyedinstruction:
-methodofconnectionofconductors:
-full-scalediagram:
-sizesanstypesofcordssuitable:
8.7
Markingdurableandeasilylegible:
15 swithhexane,15 swithwater
9
DIMENSIONSANDCOMPATIBILITY
9.1
AppliancecouplerscomplywithrelevantStandardSheet :
C
9.2
RetainingdevicescomplywithStandardSheetC 25
9.3
Single-poleconnectionsnotallowed
ImproperconnectionswithplugsofIEC 83notallowed(forconnectors)
ImproperconnectionswithportablesocketoutletsofIEC 83notallowed(forapplianceinlets)
9.4
Engagementimpossibleof:
connectorsforClass IIwithapplianceinletsforotherequipment
connectorsforcoldconditionsinapplianceinletsforhotorveryhotconditions
connectorsforhotconditionsinapplianceinletsforveryhotconditions
connectorsinapplianceinletshavingahigherratedcurrent
9.5
Pinendsdonotprotrudebeyondlimitingsurfaceoftheshroud
9.6
DeviationsfromthedimensionsspecifiedinStandardSheetdonoteffectinterchangeability
10
PROTECTIONAGAINSTELECTRICSHOCK
10.1
Livepartsofapplianceinletsnotaccessible
Livepartsandearthingcontactofconnectorsnotaccessible
10.2
Connectionbetweenapinandthecontactimpossiblewhentheotherpinisaccessible
10.3
Partspreventingaccesstolivepartsonlyremovablewithatool,and
thesepartsinsulatedfromliveparts
Bushesadequatelyfixedandremovableonlywhendismantlingtheconnector
10.4
Externalpartsofconnectorsshallbeofinsulatingmaterial
Shroudandbaseofapplianceinletwithoutearthingcontactand2,5 Awithearthingcontactshallbeofinsulatingmaterial
11
PROVISIONFOREARTHING
11.1
EarthingterminalscomplywithCl. 12
11.2
Earthconnectionmadebeforeinsertionofthecurrent-carryingcontactsandbrokenafterwithdrawing
12
TERMINALSANDTERMINATIONS
12.1.1
Rewirableconnectorsprovidedwithterminalswithscrew;typeofterminals;StandardSheetNo.C :
Nonrewirableconnectorsprovidedwithsoldered,welded,crimpedorotherscrewlessconnections :
Screwedconnectionsnotused
12.1.2
Clampingmeansofterminalsshallnotservetofixanyothercomponents
12.1.3
Rewirableconnectors 16 Aterminalsize 1acceptconductorsof0,75 mm²to1,5 mm²
12.2.1
Screwtypeterminalsshallallowconnectionwithoutspecialpreparation
12.2.2
Screwtypeterminalsshallhaveadequatemechanicalstrength
ScrewsandnutforclampingtheconnectorsshallhavemetricISOthread
Screwsshallnotbeofmetalwhichissoftorliabletocreep
12.2.3
Screwtypeterminalsshallberesistanttocorrosion
12.2.4
Clampingofconductorreliableandbetweenmetalsurfaces
Pulltest(1 min):
-pull(N) :
40 N/50 N
—
-smallestcross-sectionalarea(mm²) :
—
-largestcross-sectionalarea(mm²) :
—
-duringthetest,conductordoesnotmovenoticeably
12.2.5
Clampingofconductorwithoutunduedamagetotheconductor;torquetest:
-torque(Nm) :
—
-smallestcross-sectionalarea(mm²) :
—
-largestcross-sectionalarea(mm²) :
—
12.2.6
Terminalsize:
:
1/2
—
Nominalcrosssectionalarea(mm²) :
1,5 mm²/2,5 mm²
—
Torquetest:
conductordoesnotslipout;torque(Nm) :
12.2.7
Screwtypeterminalsdesignedsoasnottocauseexcessivetemperatures.ComplianceischeckedbythetestofCl. 21
12.2.8
Screwsandnutstightenedandloosened5 times.Duringthetest,terminalsdonotworklooseandshownodamage;torque(Nm) :
12.2.9
Screwtypeearthingterminalssamesizeasliveterminals
12.2.10
Clampingscrewsornutsadequatelylockedagainstaccidentalloosening,and
impossibletoloosenwithouttheaidofatool
12.2.11
Screwtypeearthingterminalsshallbesuchthatthereisnoriskofcorrosion
Bodyshallbeofbrassorothermetalnolessresistanttocorrosion
12.2.12
Pillarterminals,distanceg(mm)nolessthan1,5 mm(seeStandardSheetC 26) :
13
CONSTRUCTION
13.1
Forappliancecouplernoriskofaccidentalcontactbetweenearthingcontactofapplianceinletandlivecontactsoftheconnector
13.2
Fixingscrewsadequatelylockedagainstloosening
13.3
Pinsandcontactsadequatelylockedagainstrotation
13.4
Pinsofapplianceinletsshall:
besecurelyretained
haveadequatemechanicalstrength
notberemovablewithoutatool
besurroundedbyashroud
Testfornon-solidpins:
testforce100 Nfor1 min.Afterthetestnoalterationofpin
Testforsecurityofpinretention(1 h);eachpinsubjectedtoaforceof60 Nfor1 min;testtemperature(C) :
—
Duringthetestnomovementexceeding2,5 mm :
Afterremovaloftestforce,pinsremainwithinthetolerancesspecifiedintheStandardSheet
13.5
Contactsprovideadequatecontactpressure
13.6
Enclosureofrewirableconnectorsconsistofmorethanonepartandenclosetheterminalsandtheendsofcableorcord
Constructionsuchthatconductorscanbeproperlyconnectedandthecoresarenotpressedagainsteachother
Coreofliveconductornotincontactwithaccessiblemetalparts
Coreofearthingconductornotincontactwithliveparts
13.7
Forrewirableconnectors:
impossibletoassembletheconnectorwithterminalsenclosedbutwithcontactaccessible
13.8
Partsofthebodyofconnectorsreliablyfixed,dismantlingnotpossiblewithouttool
Independentmeansforfixingandlocatingpartsofthebody
Threadcuttingscrewsnotused
Resiliencyofthecontactsnotdependentupontheassemblyofthepartsofthebody
Partiallooseningofassemblyscrewsdoesnotallowthedetachmentofpartsprovidingprotectionagainstelectricshock
13.9
Earthingcontactfixedtothebody
Earthingcontactonepieceonlywithearthingterminal
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。